Quantcast
Channel: OpenPlant | AutoPLANT Forum - Recent Threads
Browsing all 4153 articles
Browse latest View live

Image may be NSFW.
Clik here to view.

RE: Autoplant General Arrangement (GA) drawiing in Document Manager

Hello Ken,There is a possiblity to lock the line number from relationship manager. Please see below screenshot.RegardsDinesh

View Article


RE: Autoplant General Arrangement (GA) drawiing in Document Manager

Hello Ken, As I know there is no way to lock specific file in Document Manager/Vision. I liked Jesse's way of document management, in this case you could set permissions for specific APP folder.Artiom

View Article


RE: Bushing

Hello Alex, Is this happening with some shipped specification or with the custom one? If this is a custom one, please check that there are no negative values in any fields (COMP_LEN, THD_ENG_M,...

View Article

RE: AutoISOGEN Error when output format set to Smart DWG

Dinesh:  I think you misread my post.  I was able to get a DXF output, but I wanted a DWG ouput.  The DWG output is what was giving me the POD Error.Packin31:  Your suggestion worked (sort of).  I...

View Article

RE: AutoISOGEN Error when output format set to Smart DWG

Mike,I knew it had to be saved back but forgot what version. Glad to hear you got them to run.

View Article


AutoISOGEN Error when output format set to Smart DWG

PSDS XM v08.09.04.52 Nov 2009Otion Switch 71 (PLOTFILE / BACKING SHEET FORMAT)If I run IsoGen with output format set to .DXF (ASCI) I get a good output.If I change the output format to Smart DWG, I get...

View Article

RE: Plastic Connections

Hello Alex,I could replicate the issue with the spec you sent us. It seems to me there is issue with the spec. I tried to use bentley default spec Mscpvc_40 and can place pipe correctly on the TEE with...

View Article

Plastic Connections

Hello,I'm using AutoPLANT SS4 on AutoCAD 2012.when working with plastic module, we use PWF end conditions.I created a spec where all the fittings have PWF end conditions.But I have problem with a TEE:I...

View Article


RE: AutoPLANT Flattener SS5 on AutoPLANT SS4 Design

Hello Alex, Please contact your Account Manager in order to process with Select renewal. Regards, Artiom

View Article


RE: AutoPLANT Flattener SS5 on AutoPLANT SS4 Design

Hi Artiom,Thank you for your help.If the account manager will process the select renewal then all the AutoPLANT Design applications will be replaced with AutoPLANT Moduler license and then I would not...

View Article

RE: AutoPLANT Flattener SS5 on AutoPLANT SS4 Design

Hi Alex,I have created a servce request 7000134835  for our Licensing team to process your request. Please note appropriate colleague will lassist you with the issue. Also, I have informed our Bentley...

View Article

RE: AutoPLANT Flattener SS5 on AutoPLANT SS4 Design

Hello Denish,Thank you for your help.I'm in touch with our account manager so please delete your request to him. I don't want to change my license file. Please see my correspondence with Artiom above.I...

View Article

AutoPLANT Flattener SS5 on AutoPLANT SS4 Design

Hello,I have AutoPLANT Design SS4 on AutoCAD 2012.I installed AutoPLANT Flattener SS5 on his machine.I am getting a message. Please see the attached file.This configuration should be working.Please...

View Article


RE: Bushing

Hello Artiom,Thank you for your help.It is a custom spec.There are no negativ values in any field. Please see the screenshot.There are no ebs files that were changed.The user set the dimensions...

View Article

RE: Bushing

Hi Artiom,I will clarify the question.Please see the attached files: Spec, Catalog, Model (contains 2 small models).The only thing that I changed in the catalog was the Comp_Len from 30.988mm to 64mm...

View Article


RE: how to generate P&ID plans Automatically from 3D Model in Openplant Modeler?

Miso,This video shows how to view both a PID and 3D model in Bentley Navigator for the purpose of design review. This is done via Bentley i-models.This does not show the creation of a PID from a 3D...

View Article

RE: how to generate P&ID plans Automatically from 3D Model in Openplant Modeler?

Hi Tony,thanks for replay,but i did not get any answer yet .. -;) is this possibility available,  to convert 3D -models, that have been in Openplant Modeler created, into PID ?and which software i need...

View Article


RE: Valve TagNumber to inherit property from Pipeline

I still can't seem to get this working. The Properties on my Pipeline, PipeRun and Fluid Regulator (Valve) are all new properties currently not existing in the schemas.I have added the new Property in...

View Article

RE: how to generate P&ID plans Automatically from 3D Model in Openplant Modeler?

MIso,This is not possible with Bentley applicaitons - you cannot convert or auto-create a PID from a OpenPlant 3D model.Regards,Tony DeRosaBentley Plant

View Article

how to generate P&ID plans Automatically from 3D Model in Openplant Modeler?

Hi all,i have  created a 3D model in Openplant Molder SS5, now i want to generate the P&ID from this 3D File, is there any suggestions ?which software is the right selection for this task ?please...

View Article
Browsing all 4153 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>