RE: Design Size of Major Pipeline and Size of P1 Pipe Run not linked?
Hello MelissaR,Maybe this will help - the way PowerPIDs pipeline/pipe run is configured is based on the STEP/ISO standard from years back. This is basically that every PIPELINE is actually tagged...
View ArticleRE: Valve TagNumber to inherit property from Pipeline
Hello Melissa,It seems that similar situation already has manual. In this example the SERVICE attribute is used to pass it to valve from pipe line.Please review this post...
View ArticleRE: Design Size of Major Pipeline and Size of P1 Pipe Run not linked?
Thank you very much Tony!I have customized my Pipeline TAG Number to include all the properties I need (including Design Size) and my annotation then is only the Pipeline TagNumber, as I need this...
View ArticleRE: Design Size of Major Pipeline and Size of P1 Pipe Run not linked?
Or otherwise: A "Pipeline" has "Design Size" in the "Design Conditions" (no "Size" -Value in the "Operating Conditons")A "Pipe Run" carrys the "Size" value for this branch of the Pipeline.So you note...
View ArticleDesign Size of Major Pipeline and Size of P1 Pipe Run not linked?
I am working with Bentley(R) OpenPlant PowerPID V8i (SELECTseries 5) - Version 08.11.10.202When inserting a Major Pipeline for the 1st time, the Design Size on the Major Pipeline and the Size on the P1...
View ArticleValve TagNumber to inherit property from Pipeline
I am working with Bentley(R) OpenPlant PowerPID V8i (SELECTseries 5) - Version 08.11.10.202Our Pipeline Numbers are structured as follows - AREA - COMMODITY CODE + SEQUINTIAL NUMBER - PIPE MATERIAL...
View ArticleBushing
Hello,I'm using AutoPLANT SS4 on AutoCAD 2012.How to set parameters for Bushing (COMP_LEN, THD_ENG_M, THD_ENG_R), so I would not get the break as shown in Screenshot?Looking forward hearing from...
View ArticleRE: Lack of Support from Support
I cannot call it a real support I agree , I dont get the answers I need just get directed to read the manual or go through the wiki and communities.
View ArticleRE: Autoplant General Arrangement (GA) drawiing in Document Manager
It is possible to create another application in Doc Mgr to store these types of drawings. We have created a seperate application with a unique regapp so that drawings/plans etc. are stored under a...
View ArticleRE: Lack of Support from Support
Just come here first, most of the support guys will post on here. As well as some fellow users ....including former support colleagues :).... Plus I get great support from some of the european support...
View ArticleRE: Lack of Support from Support
I agree with everything that has been said in reply to my original posting but that's not really the point is it? We pay a handsome fee for yearly subscription to Bentley and part of the fee provides...
View ArticleRE: Hi-Purity in OpenPlant
Hi Ian,The valves I'm talking about can be seen here under "Valves complete line brochure"local.alfalaval.com/.../valves-automation-dairy-us.aspxOr here under "Dairy Catalog...
View ArticleRE: Lack of Support from Support
Thanks for the comments, Brian. I can't argue with any of your points, but I will mention that Keith and Ron are still with us and available to you. As Jesse noted (thanks Jesse), Be Communities is...
View ArticleRE: Cloudworx for OpenPlant Modeler SS5
Hi Miso, Unfortunately Bentley Descartes SELECTSeries 5 cannot be run on OpenPlant Modeler SELECTSeries 5. Thanks, Mathieu
View ArticleCloudworx for OpenPlant Modeler SS5
Dear All,Question #1:is it possible to install Leica Cloudworx on Bentley OpenModeler SELECT Series 5 ?Question #2:how can i get Bentley Descartes SS5 installed in OpenModeler SELECT Series 5 ?many...
View ArticleRE: Combination between Openplant Modeler and Bentley Descartes
Hi Miso, Only Bentley Descartes SELECTSeries 4 can be installed on OpenPlant Modeler SELECTSeries 5, which should provide all the tools demonstrated in the video. Note that Bentley Descartes...
View ArticleCombination between Openplant Modeler and Bentley Descartes
Dear all,I just saw this Video over YouTube[View:http://www.youtube.com/watch?v=DoSHFxpqUw8&list=PL2fBixZKK80e-lfSsGGiJydJ_bX0dK18P:550:0]could anybody tell me how to get this combination between...
View ArticleRE: Autoplant General Arrangement (GA) drawiing in Document Manager
thanks guys for all the suggestions, just one other qustion on Document Manager, is it possibe to lock a file in there to make it read only. We are issuing isometrics from one model which we wan to...
View ArticleB3D_SYSTEM_UNITS & B3D_UORS_PER_SYSTEM_UNIT in PSDS XM
I'm using PSDS XM v08.09.04.52I received some .dgn files from an outside source, and the Resolution in the file is set to 12000 uors per Distance FOOT. We typically use 25400 per INCH. Our Db units...
View Article