RE: Creating own elements

I made changes to all files, in the specification element is added.Create a drawing element, as it is written on the link aboveBut when I set the item in the drawing, the ports coordinates are...

View Article


Image may be NSFW.
Clik here to view.

Creating own elements

I need to create own element and put it in the specification.  A similar form is present in the specification, but I need to modify it1. Where should I draw it ? In which format?2. In which directory...

View Article


RE: Autoplant Valve Topworks Orientation in Isogen

Hello Ken, This is limitation of ISOGEN. Directional annotations for topworks that have primary orientations (North, South, East, West, Up, Down etc) are suppressed in generated isometric. As possible...

View Article

Autoplant Valve Topworks Orientation in Isogen

Hi, When I produce an isometric with a valve in the line the valve topworks are shown but there is no note to say what is the topworks orientation (North, South, East, West, Up, Down etc). When I have...

View Article

RE: AUTO PLANT-EQUIPMENT PLACEMENT

You are correct this is a limitation. There is no option to edit the name of the location points.

View Article


RE: AUTO PLANT-UNITS SETTING

Architectural Type is used with Imperial project however, changing it to decimal will not affect. But, it would matter if one file was set to inches and other file is set to feet.

View Article

RE: Open Plant Model Server reference out piping with VBA

Unit works great when referencing out objects.I believe you have our workspace already because you are working on an SR that was submitted for a different issue. The ticket number is 7000220168, if you...

View Article

RE: Open Plant Model Server reference out piping with VBA

Hello Brian,Yes, I actually just saw that these are the same workspaces. I have used the original static queries for UNIT/SERVICE in Project\DataSet\ModelServer folder and created these for your custom...

View Article


RE: Open Plant Model Server reference out piping with VBA

Justinas,I placed these queries in the workspace and everything is referencing out now, thank you. So, if later down the road we add in a new model server node all I need to do is copy one of these...

View Article


RE: I-model export - Level state on/off

In Microstation 8 views can be defined differently. So if you change off some level in View 2 and create an I–Model they are switch off in view2. However, settings are saved for the I-model, If you...

View Article

I-model export - Level state on/off

HI,I'm using Openplant modeller to export I-model so we can review in Navigator.The problem is when exporting I-model from OPM model all levels are on but after exported I-model open in a Navigator...

View Article

Autoplant SPEC Class_Name

Where and how are the autoplant Classes for specs created?Thank you

View Article

RE: Open Plant Model Server reference out piping with VBA

Hello Brian,Yes, generally it is how it's created. You can just use any text comparison tool and see what are the exact changes between these files and the out of the box UNIT/SERVICE queries so you...

View Article


RE: AUTO PLANT-EQUIPMENT COORDINATE

Dinesh,Ok, I used the move command to change the coordinate of the pump and the ID command to determine how much to move it.  Changing the Location Point did nothing.  I re-created the point twice, but...

View Article

Spec Gen writing back to the Catalog

When i open a spec to edit it rewrites a table in the catalog.Is this supposed to happen. 

View Article


AutoPLANT Raceway Graphics

Hi, I posted this before but posting agin just to see if anybody has an answer. When we place an elbow from the Raceway module the graphics are shown as attached. It is not happening to every PC, some...

View Article

OPM HVAC Takeoff components

It appears that the takeoff component does some calculations to determine if the size that you enter will work with the duct that you are placing the component on, is there a way to turn off the calc,...

View Article


Moving from OPM SS5 Refresh (383) to OPM SS5 Refresh (404) in standalone mode

Found this...

View Article

RE: Running OPIM with AutoPLANT

Hello everyone,Sorry for the delay on this. I just saw this was unanswered. Unfortunately you can't create/edit the seed file in DWG. It must stay in DGN because OpenPlant Isometrics manager needs it...

View Article

Running OPIM with AutoPLANT

I realize this is going to be a very generic question but has anyone had any luck running Isos using OPIM in AutoPLANT. I've tried a couple of times and it says it runs successfully but when I open the...

View Article