RE: AutoPLANT Tap in branch on elbow with same BOP as Main Pipe

Hello Ken,1. Place 6" main size pipe line2. Place an elbow on the end of the pipePlacing tap port on the elbow.1. With Advanced tap port option On in the drawing preferences select elbow to be tapped2....

View Article


RE: AutoPLANT V8i 81.10.91.40 (ss4) and Windows 8.1

Hello,I have no news about the supportability with Windows 8. However, you are correct. Any upcoming AutoPLANT version release will not have Isogen with it.RegardsDinesh Solanki

View Article


RE: Autoplant Selections Dialog

Hi Ken,Thank you for the model. I have found that some of  Directional Piping System Variables are missing. I was able to repair model using below procedure:Open a new clean model in the project and...

View Article

RE: SORT_CODE FOR REPAD

Hello Ken,By default supports will not have SORT_CODE value. To input default value for supports as 103 please follow the steps below.Open the CLASS.ini file from C:\Program Files (x86)\Bentley\Plant...

View Article

RE: Tag configuration

Hi,there is a KKS workspace that you can find in the software downloads (searching for "KKS")select.bentley.com/.../MTQ1MzcyMTYyOV80LjAuMi4w;ProductKeywords=KKS+Workspace&KeywordProductId=1981The...

View Article


RE: Tag customizing

Ronit,What product are you using?We need to have Product Name and version (Help > About - XXXX SELECTseries Y, 08.11.10.xxx.Which component class are you modifying?Thank you,Tony DeRosaBentley Plant

View Article

RE: General purpose drawing under OPPID

Hi Jaques, maybe you can explain what you want to achieve?If you use the e.g. the functions in the Tools>Base Geometry Toolbox you can set any element properties like level or color and e.g. a...

View Article

RE: Tag configuration

Thank you very much Gerd.When i try to download the KKS workspace i have to confirm this message:"I attest, under penalty of copyright laws, that I own a copy of Kraftwerk-Kennzeichensystem (KKS)...

View Article


RE: Tag configuration

Hi, the link would rather be this: http://www.vgb.org/vgborg/en/startpage.htmlI have not been involved in the development of this. But from what I know from standards usage in general is that they...

View Article


RE: SORT_CODE FOR REPAD

Thanks Dinesh,Repad is not a support, see screenshot of isometric attached.regardsKen

View Article

RE: Tag customizing

Hi Tony and thank you for responding.I am using: Bentley OpenPlant PowerPID v8i (select series 5) - version 08.11.10.427I need to have a much longer tag in the P&ID, It can arrive to about 10...

View Article

RE: AutoPLANT Tap in branch on elbow with same BOP as Main Pipe

Hi Dinesh,Downloaded the pxf but that is not what I am looking for.  I have uploaded a jpg file to give you an idea of what i am trying to achieve. I have a 12" 90 deg elbow facing up and then i am...

View Article

RE: Tag customizing

Ronit,We are one step closer. Which component has the tag with up to 10 fields?These are controlled in the OpenPlant_Supplemental_Tagging schema using an ECExpression. We need specifics. What...

View Article


Tag customizing

Hello,How can i add fields to the basic tag?Best regardsRonit

View Article

RE: OPenPlant PowerPID "unhandled exception" error

Can you try the same steps in a new drawing? This exception says something  is wrong with the border. Are you using a custom Border or a default one?

View Article


Image may be NSFW.
Clik here to view.

OPenPlant PowerPID "unhandled exception" error

Hello,After defining some parameters at the PID document window in a new project, and pressing the OK button this error message appears:Attached are the details:any ideas what could be causing it? and...

View Article

Image may be NSFW.
Clik here to view.

RE: AutoPLANT Tap in branch on elbow with same BOP as Main Pipe

Hello Ken,Thanks for the steps. With the above steps as well I could generate the Iso with the dimensions. Please find below the isometrics.RegardsDinesh

View Article


RE: SORT_CODE FOR REPAD

Ok Ken,Please find below script which needs to be modified.. The name of the ebs file is repadout.ebs located inC:\Program Files (x86)\Bentley\Plant...

View Article

RE: Tag customizing

Hello Tony and thanks again.This is the tag structure: Total plantSystem codeEquipment code unitComponent codeDesignationGF0F1F2F3FnA1A2AnA3B1B2BnData characterA or NNAAANNAANNNAAANNIts a general form...

View Article

RE: OPenPlant PowerPID "unhandled exception" error

It happened when i used the at.ini file to change the file units. If now i will open a new file with the same units and thus won't use the at.ini file this problem will not recur.

View Article