RE: OPenPlant PowerPID "unhandled exception" error
Are you trying to open a file in KKS project using Bentley Vision? Could you provide your AT.INI file so that I can have a look at it?
View ArticleRE: Printing a Spec
Hello AlexIt seems you have install two version of Microsoft office uninstall one of office version.RegardsAbhijit
View ArticlePrinting a Spec
Hello,I am using AutoPLANT SS4 on AutoCAD 2012 with Office with access 2010 x64.When trying to print any spec from the specs that comes with the installation I am getting an error. Please see attached...
View ArticleRE: European DIN Standards
Hi Ian,How about ProSteel Support Modeler? Is there any development in progresss?Regards,Maciej
View ArticleRE: General purpose drawing under OPPID
Hi Gerd,Thank you for your response.Regards,Jacques.
View ArticleRE: Isometric Drawings
Hi Alex,Please check for stop signs. Also, make sure correct connection criteria is defined.RegardsDinesh
View ArticleIsometric Drawings
Hello,I am using AutoPLANT vesrion 08.11.09.140Please see the attached model. There are 2 PXF:"200-PP-12-SW-018_partial model.pxf" and "PT 5000 PIPING MODEL_00096-2014_06_17-only_18-Full.PXF". The...
View ArticleRE: European DIN Standards
Hi Maciej,If you are referring to pipe supports in ProSteel the answer is no. We are developing an Engineered Support Modeler tool that will work independently of ProSteel. It will work with OpenPlant,...
View ArticleEuropean DIN Standards
I am looking for European DIN Standards for PS Support Modeler, as the default libraries regards US Standards.Are there these kind of standards ready to be imported in the software?Bill Prassas
View ArticleRE: AutoPLANT Tap in branch on elbow with same BOP as Main Pipe
Thanks Dinesh, got it sorted.
View ArticleRE: Autoplant Selections Dialog
thanks Artiom, why would the variables be missing from a model?RegardsKen
View ArticleRE: AutoPLANT spool id in pcf
Hi Artiom,Use dthe assign Spool ID in Autoplant to give the pipe run spool identifiers an dthey come out on the PCF.RegardsKen
View ArticleAutoPLANT Isogen tapped connection scale
Hi, The scale of vents and drains is to small to read, how can I increase the size. These are on tapped connections.
View ArticleRE: Tag customizing
Ronit,If this is a KKS tag format then I suggest you download the KKS workspace environment that we have created. Under our agreement with the KKS organization we are not able to deliver this as an out...
View ArticleMISC ATTACHEMENTS FLOOR OPENING DESCRIPTION
Hi, Our designers wan tto change the default description for Misc Attachement>Floor Openeing to Thru Wall so they don't have to edit it each time.I see that under CLASS_OOB.ini there is a Long and...
View ArticleRE: MISC ATTACHEMENTS FLOOR OPENING DESCRIPTION
Hello Ken,After changing the CLASS.ini all the new Misc attachment placed will have the new class description. You will need to update the Short_desc and Long_desc of the Misc attachments you had...
View ArticleRE: MISC ATTACHEMENTS FLOOR OPENING DESCRIPTION
Hi kfitz,Changing SHORT/LONG descriptions in class.ini file [AT_ATTACH_FLOOROPENING] should change the default settings in AutoPLANT when placing new attachments. If it did not change, please make sure...
View ArticleRE: MISC ATTACHEMENTS FLOOR OPENING DESCRIPTION
Thanks Guys,I changed the long and short description on the project class.ini but stil coming out with previous descriptions, strange one.Ken
View ArticleWeld ID
Hi, I am assigning weld ID's to a piping model by type but it is limited in the types you can choose. For example Field Weld do not have a separate weld number type i.e. FW1 as they fall under Butweld...
View ArticleRE: OpenPlant Modeler - Piping new custom component
The FACING_VALUE_MAP is located inside of the OpenPlant Catalogue schema.shaun