RE: Modifying the seed file for OPIM in AutoPLANT

Hello Buffalo186,There is a good link below which has step to step information on this. Please find the link...

View Article


RE: OPenPlant PowerPID "unhandled exception" error

Just added a plant area number and 2 services at the plant tab.Thank you for your responseRonit

View Article


RE: General purpose drawing under OPPID

Hi Tony,Thank you for your answer.I understand the restrictions you mentioned. My question is how can I change momentally the setings under OPPID to use the product with the Base Microstation settings?...

View Article

Image may be NSFW.
Clik here to view.

Tag configuration

Which courses teach how to modify the tag configuration in OpenPlant PowerPID (by adding more fields to it)?This is how the tag should be in the project: G-F0-F1F2F3-Fn-A1A2-An-A3-B1B2-Bn (see...

View Article

RE: Modifying the seed file for OPIM in AutoPLANT

Dinesh,Thanks but I've been through that and it doesn't tell me anything about how to actually replace the template drawing frame. I've looked at the seed file that comes with OPIM and the template...

View Article


RE: OPenPlant PowerPID "unhandled exception" error

Please confirm the build of OPPID you are using.

View Article

RE: Modifying the seed file for OPIM in AutoPLANT

Brian,Use the OPIM tools to open the seed file for a particular project and style. From the Microstation menu bar select: File > Open and open the DWG isometric or drawing frame of interest. Its...

View Article

RE: OPenPlant PowerPID "unhandled exception" error

Bentley OpenPlant PowerPID V8i (SELECT series 5)

View Article


Image may be NSFW.
Clik here to view.

OPenPlant PowerPID "unhandled exception" error

Hello,After defining some parameters at the PID document window in a new project, and pressing the OK button this error message appears:Attached are the details:any ideas what could be causing it? and...

View Article


RE: AutoPLANT Tap in branch on elbow with same BOP as Main Pipe

(Please visit the site to view this file)(Please visit the site to view this file)Hello Kfitz,Could you please send me the pxf file for testing purpose. What are your project units?I tried your same...

View Article

RE: AutoPLANT V8i 81.10.91.40 (ss4) and Windows 8.1

Hello Mr. Packin31,Microsoft Windows 7 is supported with AutoPLANT and not Windows 8.1 yet.AutoCAD 2012 is supported with  AutoPLANT SS4. Please find attached readme for AutoPLANT as well which has all...

View Article

RE: AutoPLANT V8i 81.10.91.40 (ss4) and Windows 8.1

Dinesh,Thanks. Any timeline when it will run on Windows 8?Will we need to up to the newer version?If so we loose ISOGEN right?Tom

View Article

AutoPLANT V8i 81.10.91.40 (ss4) and Windows 8.1

I have been asked to test out AutoPLANT V8i 81.10.91.40 (ss4)  on a remote workstation that has Windows 8.1 as the operating system.If AutoCAD is not installed on the remote workstation what version...

View Article


RE: AutoPLANT Tap in branch on elbow with same BOP as Main Pipe

Hi Dinesh,Can you send me on the steps you take to model a line as I have described and can you also send on a pdf of the isometric you produced..RegardsKen

View Article

RE: AutoPLANT spool id in pcf

We have Isogen set up to generate spool ID's at the moment so that must be why they are not coming out in the PCF. If we assign Spool ID's in Piping then they will come out in th ePCF? Is there a way...

View Article


AutoPLANT spool id in pcf

When I generate isometrics from Autoplant through isogen I have the option switch set for isogen to assign spool numbers which are tagged and listed in the isometric. However the pcf file does not...

View Article

RE: Autoplant Selections Dialog

Hi Artiom, that worked but problem with the model as not picking anything when I try to PXF out.  I have exported file from Relatioship Manager for you to have a look.RegardsKen

View Article


RE: Modifying the seed file for OPIM in AutoPLANT

That did it Frank, Thanks.

View Article

SORT_CODE FOR REPAD

Hi, I want the SORT_CODE for REPADS to default at 103 as I don't wan them to be shown on the isometric. How can i do this?

View Article

RE: AutoPLANT spool id in pcf

Hi Ken, Yes this is exactly how it works, unless it is customized otherwise. As for the formatting, the spool assigning routine will use last character as increasing counter. If letter will be used as...

View Article