AP OPIM - functions defined in opcfhdr and opcfftr files
Just for curiosity, I wonder which functions would be called during OPIM export process in AutoPLANT Modeler V8i. So far, I only noticed at_PCFOut_begin() is called. All other functions look being...
View ArticleAutoPLANT SS8 Object Enablers for AutoCAD 2016
HiWe have been waiting for the SS8 release to enable AutoPLANT to be used in AutoCAD 2016. I noticed it has been released this week (finally!!).Can anyone send me a link to where to download it. I have...
View ArticleOpen Plant PID, insert assembly as Detail text
Create control assembly called “Motor Control Type 001”Draw the motor in PIDInsert the assembly linked to the motor, tag all the instruments in the assembly, but i don’t want show the assembly...
View ArticleOpenPlant drawing referenced into itself and lost links to Database
My Computer crashed the drawing I was working on has now referenced itself into itself and lost it's links to the Piping DatabaseHow can I get the reference back to being the main model of the drawing.
View ArticleATDB0107: Error Executing the SQL statement
I did the fresh installation on one of the system. After installation in piping model I am getting following message as ATDB0107: Error executing SQL statement SELECT * FROM PIPING WHERE COMP_ID =...
View ArticleAutoPLANT Object Enablers for AutoCAD 2017
I had a previous question about the OE for AutoCAD 2016 which was answered successfully.My question is now what is the plan for AutoCAD 2017? Are Bentley considering releasing a Stand alone OE for...
View ArticleOpenPlant Modeler Admin training dataset
Hi,I've just downloaded the material for the OpenPlant Modeler Admin course from the Learn Server. At the beginning of the tutorial, it states that I should install the training project dataset,...
View ArticleOld format or invalid type library error
I'm looking for help on the following error:Old format or invalid type library: (Exception from HRESULT; 0x80028019 (TYPE_E_UNSUPFORMAT))64.08.111.113 AutoplantAutoCAD 2014WIN10
View ArticleDrawing Files size has increased in OpenPlant
I had a file in OpenPlant that was 19mb. I have now re-opened worked on it and saved and it is now 203mb with very little change made to the drawing.Could it be because my preference file on my...
View ArticleWhen placing a slip-on flange and using a field-fit weld Create Iso via OPIM...
In the example below I'd like to remove the unnecessary 7/16" dimension. It should be combined with the dimension continuing off the image to the next fitting. It there a way to customize...
View ArticleOPIM - Component PART_ID
It looks like in the newest version of OPIM 08.11.11.103, PART_ID of flange, gasket and bolts are placed separately. Is it a way to let them group and without splitting line (it will look more...
View ArticleOPIM - Hatch and slope display threshold
Is it anywhere that can specify threshold of displaying slope symbol and hatch lines? For example, if slope is less than 5 degree, not hatch and slope angel showsThanks,Maggie
View ArticleOPIM_AT, Reference Dimension, Carriage return
Hi,AutoPLANT Modeler .235 with OPIM .87When adding a Misc. Attachements>Reference DimensionHow do I make the dollar sign to produce carriage return in text?See picture:
View ArticleAutoPLANT SS7 - Xchg pcf export - Continuing Components issue
When trying to create a PCF file via "Plant Exchange --> PCF --> Generate PCF" function, if "Continuing Components" is set to 0, exporting process runs smoothly with no error. However, if...
View Articleblank nominal size in pipe spec
Hi bentley,I'm using autoplant SS5. I find out my pipe spec nominal size is blank (refer photo)Why this happened? How to solve this problem?Thank you.H.Y
View ArticleOPM Holes in Vertical Tank Skirts
I have several vertical tanks with skirts with access holes(24 inches dia) in the shirts. I model the access holes with the noozle manager as a radial with a BW connection.How can I remove the skirt...
View ArticleAP-OPIM - Equipment Nozzle in ISO continuation
I am trying to make equipment nozzle tag (nozzle on equipment, not piping nozzle) to show in pipe line continuation but with no success. I am using sample MMetric project and have added a new label for...
View ArticleNotes in several boxes in OPIM
Recently we learned that you can create a note on an isometric with several lines of text by placing a $ between the lines of text that we want. This puts all the text in one box on the isometric. We...
View ArticleHEX NIPPLE FITTINGS
hi bentley,I'm using autoplant ss5, where i can get this hex nipple fitting? (please refer photo)what is the command for this fitting?thank you,H.Y
View ArticleOPIM - Line type for Pipes in ISO image
Can pipe symbol be LineString/Shape instead of just Line? The problem is we use CTB files to plot which line weight relies on color, especially for simple line, while plotting, line weigh is ignored....