AutoPLANT - Assembly Manager - Crash on insert

Hi,AutoPLANT .235 with AutoCAD 2015When inserting a new created assembly AutoCAD crashed (FATAL ERROR). Tried on 3 different machines with same result.Works fine with sample assembly.SH

View Article


Image may be NSFW.
Clik here to view.

Match Flange Facing RF/FF

I cannot get FF matched to RF using ProjectWise. I have tried the Wiki and it works on my local C:drive but not for ProjectWise. Can someone help me out?Using Openplant Modeler 08.11.09.568and PW...

View Article


Image may be NSFW.
Clik here to view.

AutoPLANT, Insulation not showing on Flanges/Valves

Hi,AutoPLANT .239When placing insulation (Show Insulation option is ON) on flange and/or valve it is not shown (graphicaly) in the model. Insulation is shown correctly on pipe and elbow.Tried to do a...

View Article

Image may be NSFW.
Clik here to view.

125LB flanged nozzle not available

Hi bentley,1) I'm using autoplant ss5. Now i'm using specgen to setup the pipe spec. I cannot find the 125LB flanged nozzle in catalog, the nozzle rating only start with 150LB. Flange 125LB available...

View Article

OPPID Schema - Last Value Used

Request was posted 4 years ago asking for Custom Attribute syntax for "use last value". Has this been implemented yet?  In my case, I want Plant Area once selected to not change until another area is...

View Article


Mix and match the asme/ansi spec with JIS std spec

Hi bentley,I'm using autoplant ss5. I'm try to mix and match the asme/ansi spec (mmcs150) with JIS std spec (mm_jis_jpi) but there is an error, its seems like asme/ansi and JIS std cannot match for...

View Article

Image may be NSFW.
Clik here to view.

AT_OPIM, How to disable dimension on existing parts

Hi,How do I disable the dimension on the existing part? I tried to add a rule in the OverRides.txt file but keep having them:#Existing parts are not...

View Article

OPPID, Open Schema, As for pid.01.07.ecschema.xml

Hi,Just begin to use OPPID for evaluation. Try to modify schema to add pipe annotation. It seems that Bentley schema technology is now the base of all their product. Why make it simple when it could be...

View Article


Image may be NSFW.
Clik here to view.

OPIM - Rotated dimension?

For some reason, dimension is in different scale and size in two size of an elbow and two ends of the grooved elbow display differently too. Can some one help to fix this?Thanks,Maggie

View Article


training centre in singapore

Hi Ashok from singaporeAnybody can advise Openplant training centre in singapore. ashokgwrf@gmail.com

View Article

Image may be NSFW.
Clik here to view.

OPPID, Auto-Routing, How does it work

Hi,Using OPPID .43Just trying to place a major process line between 2 equipments using the Auto-Routing mode. All I get is a straight line (diagonal) between them.Should it be simple?OPPID...

View Article

Image may be NSFW.
Clik here to view.

OPPID, Crash on moving end of process line

OPPID version .43Click on a process lineRight-click and Select InRun ComponentsMove the connection pointSH

View Article

Washers in Bentley Specification generator

How do I add washers in Specification generator?

View Article


OPPID, Class Editor, Re-editing property not acepted

Hi,Bentley Class Editor V8i 08.35When editing a an ECExpression on a property of a class. First change is accepted (Enter key) but if I need to modify it again it won't accept the value.Error message :...

View Article

Image may be NSFW.
Clik here to view.

Problems with gear operators in OpenPlant Modeler.

Does anyone else have problems with gear operators in OPM rotating in the wrong axis on placement?In OPM 08.11.09.581, we have an issue where placing a gear operator at any angle other than straight up...

View Article


Code error 2738 installing Open Plant Modeler 08.11.11.87

Trying install OpenPlantModeler 08.11.11.87 the istallation crash with the next error "The installer has encountered an unexpected error installing this package. This may indicate a problema with this...

View Article

Image may be NSFW.
Clik here to view.

OPPID, Valve Type not populated

Hi,Using OPPID .43When inserting a valve, the valve type is not populated in the database. How to enable it?Thanks,SH

View Article


AP V8i SS8 Project Packager

Hello,I am just getting underway with testing AutoPLANT V8i SS8 and am using Project Packager to move some data over to the new version for testing.  When I package a project, it seems that models...

View Article

How to remove project reference from external model

AP Modeler SS6 08.11.11.135 One of our pipping designers is working with AutoPlant models from a customer (version unknown).When he references in a model from the customer he gets multiple errors from...

View Article

Create Level By Line Number

Currently I place the piping components on a level corresponding to the service. (How to Set Symbology of Pipeline by Service)Is it possible to automatically create levels by the line number and insert...

View Article