EC Annotation Update

I'm testing EC Annotation and seems working so far - My question is how I can update existing annotations once I update pipe size or Tag No.I know AECOSim updates DG annotation automatically, but not...

View Article


Open Plant creating Drawings

Hello together,I have an Little Problem with Drawing creating.All Views and necessary references are ready.The Problem is when placing annotaions:1.) When Label is placed it cant be modified anymore...

View Article


Image may be NSFW.
Clik here to view.

OPIM: How to include Test Ports on Isometric's Bill of Materials

Good Day,After doing the procedure explained on Wiki: "How to Show Spool Identifier and Test Port Instrument Bubble Tag Number In Isometric",the test port bubble started to appear on the isometric, but...

View Article

AutoPipe function in AutoPLANT - length limitation?

Hi,I seldom use AutoPipe function in AutoPLANT. Recently I was told that AutoPipe function works inconstant - pipe only place in some sections. When I tested it, and figured that only short pipes had...

View Article

Openplant Project Administrator

Hi, anybody can tell me if the openplant project administrator is a separate installation or incorporated with some other application, I do not find it after the installtion of openplant modeler.thanks...

View Article


Breaking up Model files for large sites

We are new to OpenPlant and we typically work in large plants.  How is everyone breaking up a site into different models so multiple designers can work at the same time?ThanksGary

View Article

Image may be NSFW.
Clik here to view.

Trouble unpackaging project into SS6

Hi, Some whelp would be very much appreciated.I am trying to unpackage a project into Autoplant SS6 from SS2, and not having much joy.SS2 says it's packaged the project just fine and SS6 says it's...

View Article

OPPPID Drawing Revision

Openplant PID Drawing revision. Can anyone use alpha (A, B, C etc.) revisions? When I try to change the default rev "0" to "A", I get error message "Property Value is not valid". Bentley support says...

View Article


OPIM - Label pointed to same point

Hi,Using OPIM .87 with AutoPLANT .235.When extracting isometric I'm getting very strange result. Most of the label's origins are comming from a point outside of the bounderies. See picture in the reply...

View Article


OPIM - Isometric with Tee Shoe Support takes forever

Hi,I'm using OPIM .87 with AutoPLANT .235When a tee support is included in an ismetric OPIM takes foever to run in fact I had to kill it because I didn't see the end. If the selection doesn't include...

View Article

Image may be NSFW.
Clik here to view.

OPIM - Component is not connected to

Hi,Using OPIM .87 with AutoPLANT .235OPIM gives error messages about components not connected even if it is connected (conncectivity cherker didn't found disconnected component)This occurs many times...

View Article

Unable to use half coupling in open plant SS5

I am unable to use half coupling in open plant. I have added specs of the half coupling but when I select the coupling it shows only full coupling.

View Article

Unable to use auto plant instrument specs in open plant

I have tried to use (upgraded) the auto plant spec in open plant spec but while inserting the instrument no spec window pop up and no instrument can be added in the drawing.Regards,Jayant

View Article


Image may be NSFW.
Clik here to view.

OPIM wrong dimension distance when a support exists

Good Day,The isometric generated by OpenPlant Isometrics manager, has the wrong distance number on the dimension.Here are the correct dimensions on the model:But in the generated Isometric, you can see...

View Article

Image may be NSFW.
Clik here to view.

isogen dimensioning with blind flange tap

Hi when I put a tap port on a blind flange, the isogen doesn't whant put dimensioning on the isometric. When i exclude the tap point on the blnd flange, the isometric is ok. Someones know why and how i...

View Article


OPM - Assign gaskets and bolts to a different level

Hi,Is anyone aware of the steps to assign bolts and gaskets to a microstation layer other than the one all piping components are in? Our goal is to be able to select and turn off all gaskets and bolts...

View Article

Image may be NSFW.
Clik here to view.

Flexible Hose Returning Connectivity Error, cannot create Isometric

Hi All,I would like to add a Flexible Hose with flanged ends to an isometric. The problem is that the connectivity checker always returns an error between these fittings, even though there is no error...

View Article


auto router

Good day My computer has been upgraded which has resulted in my familiar settings changing.  How do I change the default auto router setting?  Changing the drawing preferences does not change the auto...

View Article

Unit testing application

Hi,We have a c# wrapper that uses the dmscli.dll.The application wrapper work fine when running through a console window or a windows form app but will not log in using the same credentials when ran...

View Article

OPIM - Tapping connection sizes limitation?

It seems there is a limitation on size when doing tapping. When I have larger different on tapping sizes (such as 2"x1"), OPIM has no problem, but when tapping sizes different is less or equal to 1/2"...

View Article