Autoplant 3d SS5 - Bill of material style & isometric dwg template

Hi Bentley,I'm autoplant 3d ss5 new user.1) How many BOM style autoplant have? Where can i setup/choose the BOM style? Can you give me the setting location.2) How many isometric dwg template autoplant...

View Article


Image may be NSFW.
Clik here to view.

AP OPIM - Text Comments location is wrong on fittings

Previously I put text comments on pipe, and they looked OK. However, when I put a comment text on a branch end, such as a plug, it points to a strange location. Originally, thought it might something...

View Article


Image may be NSFW.
Clik here to view.

AP OPIM - Continuation label

Is it possible to to place continued ISO number in second line just like continuation to nozzle?Thanks,Maggie

View Article

OpenPlant lookup from a database table

We would like to provide a MotoType dropdown to our users of OpenPlant so that when then place a motor on a PID, they can just pick a MotorType from a list.We know that we can create a lookup list by...

View Article

OpenPlant lookup from a database table - two fields

Calling two values from the table "SELECT Field1, Field2 FROM ...."  returns both values as columns in the drop list.  When you make a selection the ECProperty is assigned the value of Field1.  This is...

View Article


OpenPlant lookup from a database table - Where dbField = ECProperty value

Please help with SELECT statement syntaxSELECT Field1 FROM table WHERE Field2 ="current value of another ECProperty"Thank you

View Article

OPM & OPIM - Can't load iModel

Using the following versions;OPM - 08.11.09.564OPIM - 08.11.09.458When I generate an iModel from OPM, OPIM can't load it.  I've done everything I can in OPM to change the iModel and nothing works, OPIM...

View Article

Image may be NSFW.
Clik here to view.

AP OPIM - pipeline end coordinations

Hi,Is it a way to force coordination output on all ends of a process line? Originally, I thought it is a random case, but it looks like it happen often, especailly when one end is opened (no connection...

View Article


OpenPlant Isometrics Manager Changing Symbol Sizes for an A3 Isometric Sheet

When generating an OPIM Isometric using an A3 Seed file the scale of all fittings, valves, olets, supports etc., is too large. I need to be able to reduce the scale of the cells so that they are...

View Article


Image may be NSFW.
Clik here to view.

Autoplant Piping V8I - Isogen symbol modification

I have created 130 +/- symbols (misc., instrument, etc.) to incorporate for our company to output with the Isogen piping isometrics.  This includes the asc file and respective bin file.  Interpreting...

View Article

AutoPLANT - Object Layer Properties - Transparency

Hello,I have been tasked with creating one object over-top of another, where the desired effect is to have the outer object semi-transparent, while the inner object is not. This would be equivalent to...

View Article

Image may be NSFW.
Clik here to view.

OPPID : pid diagnostic checkforduplicateguids

Hi,When i run this Command i.e. Èpid diagnostic checkforduplicateguids"   I recieved A dialogue box (Please see below Image).Since i want to rectify this error, i dont how to delete this 2159 problems...

View Article

I am unable to load equipment in work area setup in piping file in Bentley...

hi,when I add some equipment or structure file in work area setup of piping file, it fails to add anything in the drawing, please give the solution as soon as possible

View Article


AutoPipe Dialog Box Not Showing in AutoPlant

Hi, i just started learning AutoPlant, and when i use AutoPipe features in AutoPlant SS6 the dialog box is not showing. I also got the following message "Selection Dialog was cancelled". How to fix this?

View Article

OPSE Deployment with ProjectWise integration [OPSE v08.11.09.135]

Is there a Wiki post or tech note somewhere describing how to fully deploy OPSE with ProjectWise integration? 

View Article


Image may be NSFW.
Clik here to view.

List for OPIM Skeys or say Supported Geometry type mapping in pcf.ini file

HI ,I was trying to add new symbol, for a new user defined class, in openplant modeller, to appear in isometric,Please reply for any thoughts on attached screenshot query.Regards,Vivek

View Article

Connecting Components is comes in with wrong colour

We have moved Autoplant SS6 from SS3 and in the Project Administrator we always used select color by Service option.Now since we have changed to SS6 when we place a pipe or fitting form the settings...

View Article


Copper tube bend

How to insert copper tube bend ?

View Article

Looking for job change

Hi all,I have worked for a long time in various Bentley applications and modules like Microstation, Plantspace isogen etc as user and administrator. From past one year I am working in Intergraph...

View Article

AUTOPLANT PIPE WITHIN A PIPE SLEEVE

I have a 30" pipe run where part of it requires a pipe sleeve of 36". This will be basically 30" pipe in a 36" pipe (sleeve) for part of the pipe run. I want both sizes to be shown on isometric MTO. Is...

View Article