OPPID Service Error : Deletion
Hi,Currently i am working on an Converted autoplant P&ID project in OPPIDi have found in my current drawing n number of Services which was stored in Original Autoplant Project.Please find Image...
View ArticleAutoPLANT Raceway pxf export not importing correctly
I am using AutoPLANT V8i SS4 with AutoCAD 2012. I did a pxf export and then a pxf import into another model of some cable tray. Some of the cable tray graphics, particularly vertical cable tray, is...
View ArticleAutoplant Plastic Dosing lines
Hi folks, we wish to model plastic dosing lines that are attached to our main stainless steel pipework, we do't need anything too fancy.we can see there is a 'Tubing' module but this seem to only do...
View ArticleHot Points
OpenPlant PowerPID V8i (SS5). Is there a setting that disables the hot points upon selecting an element within the drawing. I do not have hot points to manipulate process lines, equipment or anything...
View ArticleTag manipulation
What schema do you alter to add/remove fields from tagging process lines? Currently I am set at default and need to remove a couple fields from the output. In this instance I need to remove the...
View ArticleAutoPLANT AT.INI ERROR
How do you fix this? AutoPLANT was uable to read the AT.INI file.This file should be located in the following path:COMMON_APPDATA\Bentley\Plant Athens\Cfg\.Where in COMMON_APPDATA is typically the...
View ArticleOPPID Synchronization Error : Parameters in RPC Request
Hi,Initially my drawing was successful when synchronized from drawing to database,But now i am facing some sync issue when doing database to drawingits shows something like this : -because of an error:...
View ArticleOPIM - Random fastener error on manual partial selection
Recently I met an issue that when running OPIM in AutoPLANT with manual selection. If I manually select patial of the process line, even just a piece of pipe or a reducer, I got an error on fasterner,...
View ArticleWhat is OpenPlant hosted on?
Good afternoon, can someone please advice what OpenPlant is hosted on, as in backend databases.. SQL.. Oracle? Versions? Version of Windows server and recommended hardware requirements. Thanks
View ArticleOPPID : How to enable Plant Project browser.
Hi,I am using OPPID Version, 08.11.10.631.I want to edit some unwanted tags directly by multi-selection in plant project.By default in the current version it is disabled, is it possible to enable this...
View ArticleOPIM - Text nodes aren't all editable in seed file
I'm not able to edit the font size, type, etc. of all the attribute text nodes in an OPIM seed file. Strangely enough I can edit nodes 10, 15 and 36 but not any of the others. When I attempt to...
View ArticleError "ATDB0805 : Unable to get the Document ID from the project database"
Dear Bentley Autoplant Team,,We are getting Error "ATDB0805 : Unable to get the Document ID from the project database" while saving to one of the project.Please let me know the solution to fix this...
View ArticleAutoplant SS5 installer location
Hi Bentley,Can you assist me to find the location of installer for autoplant 3D SS5 from Bentley website? I want to install to the desktop with autocad 2012 & MO access 2010. This desktop using 64...
View ArticleOPIM Valve Operator Symbol in Isometric
HI ,I am trying to assign a new symbol to user defined operator..I have query as per attached screen shot ,Regards,Vivek
View ArticleCOG calculation in AutoPLANT
Recently, I was asked to calculate central weight point of whole model and I did a search on it. It looks like Isogen have ability to do it but involve a whole bunch of setup and is by line. Another...
View ArticleTextnodes.txt SQL Connection Criteria
I'm in the process of setting up OPIM to harvest database information from the AutoPLANT Process table as per the topic link...
View ArticleOPM Pipeline Manager Not Updating with Calculated Pipeline Property
I am running OpenPlant Modeler 08.11.09.440.I have a property (SERVICE_GROUP) that is populated in the CREATE PIPELINE dialog by a calculation; in this case, an sql query.When I display the Pipeline...
View ArticleEffective length factor for tapered members
HI I am using the effective length method (AISC 360-10 /ASD) to design steel Hanger with tapered members in STAAD PRO .The TABLE C-A-7.1 in the appendix 7 suppose that the section is contsant...
View ArticleCapturing the AutoPLANT model name when extracting an iso with OPIM
Hi there,I'm looking for a way to grab the AutoPLANT model name that the iso was extracted from when using OPIM, and placing that value into the iso as text similar to the txt2node & node2da...
View Article