RE: Cannot place General Wye in AutoPLANT

Hi Jesse,As always many thanks for your input. This issue is been already filed for a while as Trouble Report D-79163 and will be addressed in Auto Plant SS6.This is a link to zipped tee.ebs file from...

View Article


Cannot place General Wye in AutoPLANT

AutoPLANT V8i SS4 and SS5 (tested both)AutoCAD 2012Hi Everyone,It seems like it is not possible to place a General Wye in AutoPLANT.  I added them to the CS150 spec, and the placement starts out fine...

View Article


OpenPlant Specification Generator access files in ProjectWise

Hi,Is it possible to store all catalog files and spec files and also other needed (i.e. lookup tables) files in ProjectWise?Now we have to keep and modify all those access files in file system (C:...

View Article

RE: OpenPlant Specification Generator access files in ProjectWise

Yes, it works very well from ProjectWise. We would recommend moving the entire workspace to ProjectWise and managing all of it from there. this way, you only need to edit  and/or maintain one set of...

View Article

RE: OPM SS5 reporting for Spec sheets

thanks, I will try it out.

View Article


RE: OpenPlant Specification Generator access files in ProjectWise

Hi, I'm not sure are we talking about the same issue. What I meant is that I want to edit OpenPlant Modeler specs directly from ProjectWise with Specification Generator. If this is possible it would be...

View Article

RE: OpenPlant Specification Generator access files in ProjectWise

Pekka,Sorry yes I misunderstood. The Specification Generator has not been integrated with Projectwise. So, you must Export or Check out the specs, edit them and import or check them back in. I use the...

View Article

Viewing parts of Autopipe model

I didn't find an option to view one segment individually.Sometimes it is good for reports if I can show only each segment separate and take a snap shot for it.

View Article


Image may be NSFW.
Clik here to view.

RE: Spec Gen - Elbolet

Hi,Field Type F_EL_F_ELB means Facing of elbow to facing of elbolet. This is the resultant of Elbow Radius + Component Length.F_EL_F_ELB= 1.5*D + L, Where L = Component Length. See image below for...

View Article


Spec Gen - Elbolet

I am trying to create a new elbolet in one of our cataloges and want to ensure I have the correct dimensions.  There is a column "F_EL_F_ELB" would anyone happen to have an explanation of what this...

View Article

RE: Is anyone using SYSTEM in OPM?

Hi Justinas,This turned out to be an issue with PW Class Editor.  All good now, thank you.

View Article

Is anyone using SYSTEM in OPM?

We are trying to get the System property/relationship working in OPM for process and associated component tagging, but so far have been met with little more than pain.The property seems to work okay...

View Article

Vortex Induced Vibrations in Autopipe

Is there any documentation explaining how to do Vortex induced vibrations check (VIV) In autopipe?

View Article


RE: Piping Isometric Plant north v/s Actual north

Hello Rakesh,Kindly Update us on which version of OPM/OPIM you are using? Also you may attach the I model to test that at our end.Thanks in Advance.RegardsRahul Kumar

View Article

Image may be NSFW.
Clik here to view.

Piping Isometric Plant north v/s Actual north

HI,I'm working one of the project in OPM.My models are in actual co-ordinates and angle. Plant is spread all in 3 different directionWhen I extract Isometrics for Piping it comes with reference to...

View Article


RE: Piping Isometric Plant north v/s Actual north

Hello Rakesh,In the style.cfg file of your Isometrics style there is a variable IE_PlantNorth where you can define your custom coordinate system to be used by OPIM. Uncomment this variable and make...

View Article

RE: Piping Isometric Plant north v/s Actual north

In addition to above suggestion, Also please note that it has been implemented from 08.11.09.399 and has not been addressed till 08.11.09.383. RegardsRahul Kumar

View Article


AutoPLANT Flattener Error

Hello,I am using AutoPLANT SS4 on AutoCAD 2012. When trying to load any model in Flattener, I am getting the message attached.What can I do to solve this issue?RegardsAlex Bekkerהקלד טקסט או כתובת אתר...

View Article

OPPID - View properties with Bentley products

Good afternoon,I am looking for a list of Bentley products that we can use to view the OPPID component properties? I have tried with standard MicroStation and Navigator but to no avail.Can anybody help...

View Article

RE: Error Message : “FATAL ERROR : Unahandled e0434352h Exception at fe17940dh”

Respected Artiom,I uploaded the export package of sample drawing on Bentley secure upload section.Please have a look on high priority.Waiting for reply.