OPM CE - Spec Incompatible with Current Project
I'm revisiting this again as our list is growing.I have specs created in a different workset that I have copied into a new one. I have the workset in PA, but when I try to open the spec through Spec...
View ArticleExternal Database Custom Double Type Attribute
Hi! There are several posts on external database connections like...
View ArticleOPM CE - Flow Arrow on Small Section of Pipe
I need to get a flow arrow on some small sections of pipe, but due to the arrow size, it shoots off away from the placement point:Is there a way to edit the arrow size to stop this happening?
View ArticleOPM CE - Note Cell on Blind Flanges
I'm having an issue with some Note types where the cell symbol won't place on the flange, instead it ends up way out in space.Strangely, placing an Iso Break works fine:Anyone else have this happen and...
View ArticleOPIM CE - Same Line Number Across Multiple Models - Isometric Numbers
I've come into a situation where we have the same line number across multiple files. Can I run the from each file at the same to to get the correct iso numbering?If you run each file separately you get...
View ArticleOPM Upd9 Bolt length (not from spec)
HiIs there any way to get the results of the bolt calculations of the length of the bolts to a property on the bolt?I mean NOT the spec value. The calculated value(gasketthickness+flangethickness and...
View ArticleOpenPlant C# Addin - Connect to Microsoft Access .mdb file in 64bit process
Hi,I am developing a C# Addin for OpenPlant Modeler Connect Edition that reads data from the specification db (.mdb, Microsoft Access).How OpenPlant connect to Microsoft Access Database (.mdb), for...
View ArticleIs there a replacement for Bentley Instrument & Wiring?
Is there a replacement for Bentley Instrument & Wiring? We have been using this package over the last 5 years with great success and happy clients.
View ArticleRemoving or hiding visible structural nodes/points
How can I remove those pink dots (at the corner) or at least hide them? I'm trying to take a snapshot of the model for presentation, but those are such an eyesore. Some are at the structural point...
View ArticleOpenPlant: Schema Update Update 9 --> 10
Good morning,yesterday I have tried to shift to OpenPlant Update 10 from Update 9.While trying to upgrade the schema I always got following error:I have tried this in our network folder and in the out...
View ArticleError on OPM CE Item Details
Dear All,I tried exporting item details like pipe, fittings & valves from OPM CE explorer tool. But one error comes out and it didn't save as excel worksheet. Could anyone knows how to solve,...
View ArticleText overlap in openplant PID metric only
I am having a very weird issue where when I place an instrument with text in it, the text just overlaps, only happens in metric though.
View ArticleOPIM CE - Bolt_Dia as Mxx in BOM
As per the image above, our specs have been updated to have the bolt_dia change to the Mxx number.Problem I have now is that this field is now blank in the iso bom.Is there anything I need to do to...
View ArticleOPPID: Instrument Bubble Size
Hi everybody,we have a project with relative long instrument tagging (number). So I have changed the typical round bubbles to oval bubbles for all instrumentation.For this reason I have define a...
View ArticleUnpackage Error
While i unpacking the Autoplant model i got some error while i open the document manger and relationship manager i cant able to open the file
View Article[OPIM 10] Disable desktop shortcut during installation
Hi,Is there anyway to disable the desktop shortcut option during installation? Apparently desktop shortcut is now a required feature for installation? ...Best regards,Tuan Le
View ArticleSuppress angle less than 5
We need to suppress the angle info, if less than 5 deg. while generating ISOs. We are using the latest version as of Apr2022.
View ArticleOPPID: Dialog Box for Inline Fittings e.g. Strainer, Steam Trap, Filter
Hi everybody,I am wondering if and how it should be possible to activate the Tag Dialog Box for some inline fittings e.g. Strainer, Steam Trap, Filter.Actually OPPID just placed them inline without any...
View ArticleOPPID: Line Jumper
Hi Everybody,I have an issue with the line jumper setting.Normal Pipelines (Major, Minor,....) does not break up, when they are crossing each other. I have tried different settings. The PID_Jumper...
View Article