Channel: OpenPlant | AutoPLANT Forum - Recent Threads
Browsing all 4153 articles
Browse latest View live

Image may be NSFW.
Clik here to view.

At_piping Error Autoplant Piping

Hi,When i opened piping drawing its shown like this i cant able to work 

View Article


Overland Pipeline - What Software

Hi AllWe use OpenPlant for all our 3D Plant and Piping design, but we always get stuck with long overland pipelines.Has anybody got any suggestion on Bentley software that can do this task.Specifically...

View Article


Whats New in OpenPlant Modeler 10.09.02.11

A few days ago a new Modeler update was released and I would like to know what exactly was updated here. 

View Article

OpenPlant Modeler Facing (U8, U9)

Since the introduction of Update 8, facing no longer works as it used to. Only pairs of values are connected with each other. When will this be solved ? 

View Article

Image may be NSFW.
Clik here to view.

Open plant PID compress unused levels

Hi,How to remove unwanted levels in Open Plant PID for reference given below snapshot, 

View Article


Image may be NSFW.
Clik here to view.

OpenPlant Isometrics Manager - Realistic Pipe Length

Is there a way to represent pipe lengths in isometrics more realistically ?Thanks in advance.

View Article

Image may be NSFW.
Clik here to view.

OpenPlant Specification Generator - Class Browser is empty

I have a problem creating a specification from any catalog.When I add a section the list of available classes is always empty so I cannot add anything.Log file is always empty…OpenPlant Project...

View Article

OPM CE - Project Administrator in a Customised Build

I'm having all sorts of issues getting OPPA to run alongside my modelling build.It doesn't fill me full of confidence when there seems to be so many typos in the delivered cfg...

View Article


Image may be NSFW.
Clik here to view.

Slab Features in OpenPlant Modeler iModel Missing

HelloJust wondering if imodels that are generated from OPM can process features in a slab that was modeled in application.  The slab is currently modeled in OPM and not OBD as a temporary solution but...

View Article


Import cable diameter

Hello Everybody,Is it possible to import the cable diameter values per cable list into BRCM?So they do not have to be configurated in the cable settings, instead, we would like to import them each time...

View Article

Image may be NSFW.
Clik here to view.

BRCM reducer

Here I define a new cable ladder.But the reducer description in BOM is lost.How to add it?

View Article

Image may be NSFW.
Clik here to view.

Attribute file for each Pipeline in manually

We are updating custom attributes properties for each Pipeline in manually for each component. like Operating Pressure, Operating temperature, Design temp, Design pressure, paint properties. Please...

View Article

Image may be NSFW.
Clik here to view.

OpenPlant Project Administrator log is always empty

Hi all,why OpenPlant Project Administrator log file is always empty?It create more log files of 0KBI want to check Specification Generator logs for example. I enable logging and set "Info" level on...

View Article


Transparency from element templates

We have set our transparency of pipes to 0 in our element templates.  For some reason we are not seeing it stick though.  If a user changes the active preferences it will over ride the template.  BUT,...

View Article

Image may be NSFW.
Clik here to view.

BRCM BOM customize

Hi Gents,How can we add report information in field list?If I want to show the raceway ID in Detail_BOQ, How to do this?

View Article


Image may be NSFW.
Clik here to view.

BRCM Cable ladder and cable tray

HI Gents,Once we make the raceway model, both the cable ladder and cable tray are belong to the same level.See the example as show below.If I only want to show the LV cable tray, How to do this?

View Article

OPM CE - Report by Component OD, Not Just Pipe

New to using reports and looking to develop the 'BOM By Line Number'.Issue we have is that components connected to a reducing tee are reporting back to the main pipe size rather than the branch...

View Article


OPPID CE / Plantsight - Pipeline - From/to property

Hi everybody,I am looking for a solution to get the "From/To" property from pipelines (not Pipe_run) to Plantsight and to the page connectors.And the one hand, we need this information for the pipeline...

View Article

Iso genertion Openplant Isometric Manager CE U8

Hi Dear all, hope you are good!I'm traying to generate isomeric in OPIM by ProjectWise,- Pipes are connected (connectivity checker) OK- Isosheet generated (autogenerate iso-sheet) OK*  but when call...

View Article

OPIM CE - Iso Coordinates not Matching Model

Our models use a renamed global origin and I have edited the iso build with the Plant Grid origin, but the coordinates in the iso's don't match the model.Is there anything else I should check for?Thanks,

View Article