Re: Nominal Size with decimal places on isometric Drawing
Hmmm.. I've never tried it but if it would work I would think it would be option switch 41 in the OPL file
View ArticleOPPID Plant Areas, Systems and Services
New to OPPID SS5 and have some basic questions.Having created some initial Plant Areas in a new P&ID's, I now want to get rid of them. Although I "remove" them from the Plant tab of the P&ID...
View ArticleRe: OPPID Plant Areas, Systems and Services
Jeff,The PLANT_AREA, SERVICE, SYSTEM and UNIT all write to separate tables in the plant project database. The tables are named OPPID_AREA, OPPID_SERVICE, OPPID_SYSTEM and OPPID_UNIT. These tables will...
View ArticleRe: Nominal Size with decimal places on isometric Drawing
Option Switch 41, doesn't work with this
View ArticleRe: Data selection from external database with filter
Hi TonyDo you have any ideas based on my updated email.... I am a bit stuck on this one.Hope to hear from you soon.ThanksSpyker
View ArticleRe: ID BUBBLE RADIUS
Hello, Unfortunately, It seems to me there is no way to regenerate ID Bubbles so they would meet current ID Bubble Radius.Regards, Artiom
View ArticleUnable to create new project in Win7-64bit having Bentley V8i(SS4...
Respected Bentley Team,We just upgrade our old PC to new Dell Precision T3600 workstation with Win7-64bit and Bentley V8i(SS4 v8.11.9.140) , Autocad 2012(64bit) , Naviswork 2013 and MS-Office 2010...
View ArticleRe: Unable to create new project in Win7-64bit having Bentley V8i(SS4...
Hello Swapnil M Gholap, I have seen similar message when user did not have enough permissions to modify files in project creation root. Could you please check if the user has sufficient permissions? As...
View ArticleRe: Data selection from external database with filter
Spyker,I have not been able to find a way to have the query from one property be used as a filter in another property.The only way I can think of doing this is to build a series of instrument classes...
View ArticlePlantSpace - Configuration
We have moved forward from PlantSpace Equipment and Piping to OpenPlant but still have one project using PlantSpace Raceway. We are continually getting error messages that on 15 min are left in trial...
View ArticleOPPID : Strange error messages when converting pipes from Plantspace PID XM
Good afternoon,When converting PID's from plantspace PID XM to PowerPID I get this message:After conversion, some of the pipes from wich the ID's match with the ones in the errors are not...
View ArticleOPPID SS5 - Creating and adding Company or Client Borders
I'm going to start the task of accumulating customized symbols into OPPID by putting the borders we use. I'd like to use the same format when starting a new file and having the titile block information...
View ArticleRe: Data selection from external database with filter
Thanks a stack for the feedback...Spyker
View ArticleRe: OPPID SS5 - Creating and adding Company or Client Borders
You could just exchange the existing graphics in the delivered cellib.To gain level administering OPPID requires some knowledge that goes beyond the forum. The quickest and comprehensive approach would...
View ArticleRe: Unable to create new project in Win7-64bit having Bentley V8i(SS4...
Respected Artiom,Following are the result shown in . Login by - Drive(Project created on drive) - Result(Project Created)Regular piping user...
View ArticleRe: Unable to create new project in Win7-64bit having Bentley V8i(SS4...
Dear Swapnil, Could it be that the AutoPlant was installed using Standard user? It is recommended to perform AutoPlant install using Administrator account. Once AutoPLANT is installed it is recommend...
View ArticleRe: Unable to create new project in Win7-64bit having Bentley V8i(SS4...
Respected Artiom,We always installed all software under admin login only.After successful installation, we are assigning the workstation to our user.Then all users login the workstation with their...
View ArticleRe: Unable to create new project in Win7-64bit having Bentley V8i(SS4...
Thank you for your reply.I am not sure what could be cause of this issue, but still believe it has some relation to user permissions. Could you please check if user have full control permissions on...
View ArticleError coming "PIP_0701 : Invalid size for demo version" while working in...
Respected Bentley Team,We just upgrade our old PC to new Dell Precision T3600 workstation with Win7-64bit and Bentley V8i(SS4 v8.11.9.140) , Autocad 2012(64bit) , Naviswork 2013 and MS-Office 2010...
View ArticleRe: Error coming "PIP_0701 : Invalid size for demo version" while working in...
Hello,Please Launch License Management Tool and go to Tools > Send logs now. If everything is fine with the license AutoPlant should be activated. In case this will not help, please create Service...
View Article