HOW TO IMPORT PIPING BY LINE NUMBER OR LAYER FROM OLD EXPORT PACKAGE
Dear All, I want to Import piping by line number or layer from my old Export package. Is it possible to import line by number in Bentley Autoplant piping.If it is possible. Please help me....
View ArticleRe: HOW TO IMPORT PIPING BY LINE NUMBER OR LAYER FROM OLD EXPORT PACKAGE
Hello Shrinivas , It seems to me that there is no way to import from Export Package by Line Number. However, you could import all the drawings to a new project and then using PXF Export to export whole...
View ArticleInsulation of equipment in different color/ layer.
Hi All, Whenever we are adding insulation to equipment it is showing same color as that of equipment, so we are unable to distinguish between insulation & equipment. Is there a way to have...
View ArticleSAME COLOR FOR SAME SIZE OF PIPING IN 3D MODEL
Hi All,We want same color for same size of piping in 3d model while modeling. Please provide the settings for the same.Thanks in advance. Kind Regards,Shrinivas Jadhav
View ArticleRe: multiple entries into the database? why?
THE EXAMPLE YOU GAVE ME IS NOT THE CASE WITH MY PROBLEM. I HAVE A PIPE THAT GOES FROM A BOILER TO A STEAM DRUM, THERE ARE ONLY TWO CONNECTIONS, YET DATA MANAGER IS SHOWING 5 COPIES OF RUN 1 SHOWING THE...
View ArticleRe: OPPID SS5: How to get service from pipe run into instrument?
Sanna,I have discovered that the Notfy Related Component of Property Value Change custom attribute MUST have the "Related Class Name" field explicitly defined - IE oppid:PIPING_COMPONENT.In my case I...
View ArticleRe: SAME COLOR FOR SAME SIZE OF PIPING IN 3D MODEL
Hello Shrinivas ,In Drawing Preferences select color by size. For existing components use redraw function (Piping>Piping Tools> Representations> Redraw).I hope this will help.Regards,Artiom
View ArticleRe: multiple entries into the database? why?
Thank you very much for your reply. The example I gave is one of the cases that could show duplicates in Line List - Pipe Run. As well "duplicates" are shown when To/From arrow are used. In case pipe...
View ArticleRe: SAME COLOR FOR SAME SIZE OF PIPING IN 3D MODEL
Hi Artiom,Thanks for your reply. I want add color by size before modeling piping means whenever I model the line I want to get the line color automatically by size. i.e. Whenever I model line of...
View ArticleRe: OPPID SS5: How to get service from pipe run into instrument?
Sanna, As per our private email - this is now resolved. The need inlcuded inline FLOW ELEMENTS and though these are instruments they are related to the pipe run via a different relationship. Instead of...
View ArticleRe: OPPID SS5 - Entering engineering data other than element information dialog
Mark,Is your Project PCF file pointing to the proper project root directory and project ID?The line the PCF should look something like this:From the default OPPowerPID_Imperial.pcf file:# AutoPlantDB...
View ArticleChanging Line length
How do I change the pipe line length after I have modeled it in PlantSpace?
View ArticleRe: OPPID SS5: How to get service from pipe run into instrument?
Hello Tony,Thank you for your help!- Sanna
View ArticleView Datasheet number in all AP P&ID Data Manager Tables
Hi,I'm trying to figure how to put the datasheet number in all the Data Manager database views (Equipment Lists, etc.), because at the moment it appears only in the instruments table.Thanks in advanceGG
View ArticleRe: OPPID SS5: How to get service from pipe run into instrument?
Sanna,Is the passing of Service from Line to Run to In-line and On-line components now working?If so - I am glad I could help and thanks for your patience.If not let me know and I will get the issue...
View ArticleID BUBBLE RADIUS
IF YOU CHANGE THE BUBBLE RADIUS IN THE DRAWING PARAMETERS BOX IN AUTOPLANT, IS THERE A WAY TO GET BUBBLES ALREADY PLACED ON THE DRAWING TO UPDATE TO THE NEW SIZE?DO YOU HAVE TO DELETE/ RE-INSERT ALL...
View ArticleRe: Component preferences will not load (Series 4 with AutoCAD2012)
Hi Swapnil,Here are some brief answers to your questions:1. The greatest limitation of using an Access database is that they are not able to effectively handle multiple concurrent users. This makes...
View ArticleWHAT DO YOU HAVE TO DO TO EDIT USER EQUIPMENT?
IS THIS POSSIBLE, OR DO YOU HAVE TO ERASE AND RE-CREATE?
View ArticleRe: OPPID SS5: How to get service from pipe run into instrument?
Tony,Yes, now it's working. Instrument and valve can get the right service-property automatically.- Sanna
View ArticleNominal Size with decimal places on isometric Drawing
We have some OD base piping Specifications, where sizes are like 101.6mm, 76.1mm etc.We created seperate catalog and Spec with components having main sizes as mentioned above.When we extract Isometric...
View Article