Error when generate isometric dwg ater using isometric stop sign
Hi Bentley,There an error when i generate isometric dwg after i add the stop sign on 3D model. (refer photo)So I delete this stop sign and then try generate iso again, but this error still appear.I...
View ArticleOPM Nozzle with a wafer item has no bolts
OPM version - 08.11.09.440Using the out of the box Metric specs and project I placed a vessel with 2 Nozzles both 350mm diameter from the mA1-OPM spec.Placed a spectacle blind on one of the nozzles...
View ArticleAngle valve that isn't 90 degree (i.e. Strahman valve)
Is it possible to insert an angle valve that has a angle greater than 90 degrees? I need to use a Strahman sampling valve, normally for us these are manual sample points so I do not need to worry about...
View ArticleOPIM with OpenPlant Modeler using textnode.txt to add extra data from...
I can see that using the textnode.txt file as part of the AutoPLANT isometric generation works, but can the same thing be used in OpenPlant Modeler?I'm using it the same way to try and connect to an...
View ArticleAutoPLANT Relationship Manager import drawing error
I am using AutoPLANT V8i SS3 version on AutoCAD 2011. Part of our project is being done in another office which has exactly the same setup etc as ours. I have exported a bunch of drawings using...
View ArticleOP Spec Generator CE Reports are missing
Hello,I`m wondering with OP Spec Generator how can I spit out spec reports? In V8i I use to define reports and it would create them.In CE when I go to (Define Reports - nothing happens....Does anyone...
View ArticleHow to Import Services (names and descriptions), into a OPM Connect DGN?
Is there an efficient way to import services and descriptions (defined in a V8i OPM DGN) intoa OPM Connect DGN (which is going to be used for a OPM Connect seed file?Cheers,IT
View ArticleAlign Pipe by BOP?
How to align Pipes by BOP These pipes should be aligned vertically by BOPIs there any way of snapping to Quadrants?How to achieve?
View ArticleBolts are not coming for stud end flanges connection, how to solve this ??
Hi,We are using customized Open plant module for GRE pipe modelling.while connecting flange to flange joints, gasket & bolts are coming there is no joint error.But while we connecting stub end...
View ArticleAutoplant template generator V8i (SELECT series 8) with ACAD 2016 menu ribbon
I'm trying to follow the tutorial for Autoplant instrumentation and wiring, in chapter 5, section adding a new auto-generated template to a project... after open the template generator I have to select...
View ArticleDouble Block &Bleed
Hi seem to remember have seen a recipe for defining this as a user component from spec and cell, but can not find it.Any help is appreciated
View ArticleOPM CE copy OPM entities from reference
How to copy OPM elements from reference file?With reference to same in v8i...
View Articlepipeline manager grids customizing
Concerning grid display in PipeLine Manager, Component placement and others.Yes these can be customized by user by turning on and off and rearranging columns.Is there a way to customize these up on a...
View ArticleOPM CE snapping to OPM entities
How to measure distance between pipe, or distance from any OPM entity to other object?Based on not being able to snap to OPM entities, and not being able to drop these objects.....
View ArticleOPM CE ProjectAdmin and SpecGen
From where does Project Admin & SpecGen read their config?
View ArticleOPM Custom component levels
Hello, I have a question concerning creation of custom components. When I create a custom component it is placed in Default level and I can not change it to my pipeline level. Is there any solution for...
View ArticleError in OPSE: UILink is invalid or contains no instances. UILink must...
HelloI am develloping new placement procedures in OpenPlant Support Engineering V8i (SELECTseries 6) Version 08.11.11.235 Windows 7 x64I have very simple script:Object1 =...
View ArticleAssociate a P&ID in Instrument and wiring without Autoplan P&ID
Hi,I'm new using Instrument and Wiring tool, in the company we have the autoplan suite with the following applications:- Autoplan Modeler- Data manager.- Document Manager- Instrumentation & Wiring-...
View ArticleHow to Customize Report using Transformation Matrix?
Hello Everyone!We are required the customize report format which will be going to use for our automatic pipe bending machine.i.e pipe with pipe bends etc.currently am trying to generate report with...
View ArticleI NEED AN AutoPLANT TRAINER
Good day.Please i urgently need a trainer to train some people in AutoPLANT.Contact me:Emeka Ohuche.+2348038076733, +2348098924848Cohuche@makon-group.com.Thank you.
View Article