Hi,
We are using customized Open plant module for GRE pipe modelling.
while connecting flange to flange joints, gasket & bolts are coming there is no joint error.
But while we connecting stub end flange to stud end flange there is an joint error, due to missing of bolts.
We have tried lot in checking in supplement schemas & joint class but could didn't solve this issue.
kindly help me to sort out this issue.
For easy reference pls see below screen shot
Stud end to stud end connection
Flange to flange connection
Thanks
Regards
Prabhu S