OPIM SS6 - supress leader on continuation label

Hi,Can I turn off the leader attached to the continuation label? Best regards,Tuan

View Article


OPIM SS6 - Modify Continuation label between 2 pipelines

Hi,How do I modify the content of the continuation note between 2 pipelines. I can modify the continuation label when 1 line spans several sheets.What I want to change is the continuation label going...

View Article


OPIM SS6 - How to show full line number in continuation label between sheets

Hi,How do I set the continuation label going between sheet 1 to sheet 2 of a pipeline to show the full linenumber + sheetnumber. I would have thought using the $(LINENO)-$(SHEETNO) in the configuration...

View Article

Spec Gen - I need to know how avoid threaded valves or fittings below sch40 pipe

If there is a sch10 pipe in a spec I want to avoid putting a threaded fitting or a valve. Currently we put threaded valves or fittings only with Sch 40/80 nipples.

View Article

ProjectWise Explorer - checkout drawing is not valid

One of my designer has a AutoPLANT model, when open as ReadOnly, everything looks fine - file size correct (34MB, big, but good), components can be read properties. However, once we want to check it...

View Article


Image may be NSFW.
Clik here to view.

OpenPlant Administrator / Specification Generator

Hello!I'm in trouble with OpenPlant Administrator. When I run it, I see that symbol of my project in projects tree is not yellow as others, but green. Then, when I run SpecGen, I get an error (see...

View Article

OPM SS6 - Default spec attributes

Hi,Is there a way to set default values for a spec, say a spec's design pressure, test pressure, temp etc. Best regards,Tuan Le

View Article

OPIM SS6 - Assign P&ID drawing number for pipeline

Hi,How can I assign a P&ID drawing number for a pipeline? There doesn't seem to be an attribute available for it in OPM. Best regards,Tuan Le

View Article


Need At_Reboids Object Enabler for AutoCAD 2015

I tried previous links that have been posted but it sends me to a page that says "Link Expired". I need to bind drawings from a client that were created with these.

View Article


OPM SS6 - Threaded tap port

Hi,Just wondering how does one go about to place an NPT port on a component? more specifically, pipe and flanges? I tried the place tap port tool, but it seems to place a welded tap rather than...

View Article

OPM SS6 - component with BSP threads

Hi,Can I define a component with BSP thread? And have OPM set up so that only component of the thread type (NPT vs BSP) connect with each other.Best regards,Tuan Le

View Article

Open plant pipe routing

Before routing, how to set pipe connection (long radious/short radious/flanged connection)?

View Article

OPM Bolt calculation, wafer item connected to Flanged Item length is incorrect

Placing a wafer item after a valve that has flanged ends (not wafer) will give incorrect bolt lengths as it adds the length of the valve not the flange thickness in the bolt calculation.To replicate...

View Article


Image may be NSFW.
Clik here to view.

WIKI entries - Path to classes

Hi,May I ask for better information regarding navigation to schema classes. For example, this following wiki entry:Instruction: 4. Select Equipment NOZZLE class and edit Continuation....It would really...

View Article

Image may be NSFW.
Clik here to view.

OPIM SS6 - mapping for custom OPM pipeline property

Hi,Say I have a custom property for PIPELINE in OPM, named PID_NO. Is there away to map that to OPIM? Essentially what I'm looking for is some process similar to thisBut for pipelines, not...

View Article


OPIM SS6 - Debug.txt file

Hi,With other applications (AECOSim, Microstation, OPM etc.), using the command line -debug will produce a snapshot of the configuration variables processing and their values during startup. Is there...

View Article

Image may be NSFW.
Clik here to view.

OPIM SS6 - Show all mating flange labels

Hi,It seems when there's a matting flange connection, only 1 flange label is shown. Can I turn on the other flange's label as well? For example, in the snapshot below, I would like 2 F2 labels, 1 for...

View Article


JOINING PIPES AT AN ANGLE WITHOUT ANGLE at a certain angle (let's say to 20...

I want to join two piece of pipe, that are under cerain angle to each other (let's say 15 degrees) but I can't use elbows (I must specyfy just pipe).Summary: I want to have possibility to join pipes to...

View Article

Navigator V8i SS6 clash detection licences Y/N

Hi, stiil trying to figure aout when we have Y/N a clash detection license included.In Navigator V8i SS6 it is clear we need an extra clash detection license. It runs for free 30 or 7 days and after...

View Article

Is there a list of properties of all components?

Hello,I'd like to know the properties of all components, I can get the properties once I placed it, but it is too many... I'm wondering if bentley has such document? Thanks a lot!

View Article