Re: ATDB0719 Relationship Manager error code -213131

Thnx, it's useful advice for me) Just in my situation i changed value of Service!

View Article


Re: AutoPlant ss3 win 7 64 bit and XP sharing project

There were some issues in  AutoPlant 08.11.08.151 related to document open in 64 and 32 bit systems. If there is a way to avoid using different environment, possibly it would be the best. It seems this...

View Article


Image may be NSFW.
Clik here to view.

AutoPLANT V8i (SELECTseries 4) don't install autocad2012 xp sp3

Openation system is WINXP SP3AutoPLANT  V8i (SELECTseries 4)  AUTOCAD 2012office 2010but don't  installation

View Article

Image may be NSFW.
Clik here to view.

component preferences of autoplant is null

Openation system is WIN7 64bitoffice 2010AutoPLANT  V8i (SELECTseries 4) AUTOCAD 2012 component preferences of autoplant is null 

View Article

Re: AutoPLANT V8i (SELECTseries 4) don't install autocad2012 xp sp3

Hello , Please check that the MSVCR71.dll in is in: C:\Windows\System32This file is a part of .Net Framework. Search the pc for this file and copy it to the locations listed above.I case this is WinXp...

View Article


Re: component preferences of autoplant is null

Hello  Kanjunlin, I have met something similar to this issue when Windows text size was set to Medium – 125%.This was filed as Trouble Report D-120558. Please check Windows text size and if it is...

View Article

Re: OpenPlant PowerPID - Tag placement order

Hi TonyThanks for the feedback.  My question is a little bit different, I think.I have 2 separate properties that I want to automatically place with the symbol.  The positions cannot be automatically...

View Article

Re: component preferences of autoplant is null

Dear Sir: I have check my computer. Windows text size that  it is to 100%, and how check component preferences.thank you

View Article


Re: ERROR LOGS ON SEWER CAD 5.5

Hi Tolu,Sewer CAD questions should be posted in the Hydraulics and Hydrology community as they are not Plant products and it is unlikely that anyone reviewing this group would have any knowledge of the...

View Article


Re: OpenPlant Isometric Configuration File

This setting has been de-activated in SS5. It was the intention to have a similar formatting configuration for other (dimension) values as well but it never made it to the new user interface Frank

View Article

Re: OpenPlant Isometric Configuration File

So are there any work arounds to be able to customise the isometrics?

View Article

Re: component preferences of autoplant is null

Is this appears in any project? Try to create new project and check comportment preferences availability. In addition try following: Set NETCONTROLS=0 in the C:\ProgramData\Bentley\Plant...

View Article

OPPID: Creating relations when converting from PSPID

Good afternoon,i'm trying to convert plantspace PID XM drawings to OPPID. So far things are working pretty good but I come up with the following issue:I have a pipeline that contains a rupture disc....

View Article


Re: OPM SS5 dublicate GUID

Ive recieved a fix for dublicate GUID from Bentley. Dont want me to distribute it so Richard if u havent already made a ST you should.

View Article

Re: OPPID: Creating relations when converting from PSPID

In PSPid_ansi_Conversion.01.02.ecschema.xml, search for the "PID_LINE" class. Examine the "RELATIONSHIP_MAPPING_ATTRIBUTE". Add your class name to the  <JSM_CLASSNAMES> list.

View Article


Re: OPPID: Creating relations when converting from PSPID

Hi Steve,I allready did that. I even created a complete new jsm object for a rupture disk. Still no relations...Any other suggestions?Kind regards

View Article

OpenPlant Power PID Place Instrument Parametric

HiHas anybody figured out or found a document on how the Place Instrument Parametric function works.  I am trying to get custom cells to work with the dialog box, but not having very much success.I...

View Article


Re: OPM SS5 dublicate GUID

Thanks Jojje for the heads up. I had made a ST and have been sorted as well.

View Article

Re: OpenPlant Power PID Place Instrument Parametric

Spyker,Standard instrument bubbles are created programatticaly. They are not "cells". If you have a unique cell you want to place look at the "INSTRUMENT_CELL and INSTRUMENT_CELL ANNOTATION. These...

View Article

Re: OpenPlant PowerPID - Tag placement order

Spyker,This is strange. I just added an annotation custom attribute to DESCRIPTION for equipment class. The Tag Name property of course already had the annotation custom attribute.I set both properties...