Re: OPM SS5 dublicate GUID
Richard,If you want to move from 08.11.09.129 to 08.11.11.123 you should be doing the recommended upgrade procedure.However if you want to move from 08.11.11.111 to 08.11.11.123 it can be done normal...
View ArticleRe: custom BOM for autoplant
Hello Roby, Bill of Materials as Reports are based on Crystal Reports (.rpt files in C:\Program Files (x86)\Bentley\Plant V8i\Reports). In order to create custom BOM existing report should be modified...
View ArticleRe: OpenPlant PowerPID - Tag placement order
Spyker,Look at this post in the Plant Design Engineering Wiki:communities.bentley.com/.../4488.aspxThe key is to set the ECExpression in the order in which you need the tag format to be.In your case...
View ArticleRe: Conflict version? Bentley AutoPlant V8i SS3 Piping and old version.
Hi Barabas,Do you know what the old project version was? Also are the drawings still in the project, or were they extracted from the project?
View ArticleRe: Conflict version? Bentley AutoPlant V8i SS3 Piping and old version.
Hi.. yes, old project was done in ss2. but now company uses ss3. drawings are still in the project. i can open it from document manager. but piping is not load when i open it.
View ArticleRe: Conflict version? Bentley AutoPlant V8i SS3 Piping and old version.
Can you get the entire error string from the command line in AutoCAD? (Can use F2 to preview the dialog in ACAD)Can you load piping after the drawing has been opened or does the appear again?
View ArticleRe: Conflict version? Bentley AutoPlant V8i SS3 Piping and old version.
yes, i'll do it on monday.. when i open this drawing piping doesn't load in every cases. error appears again.
View ArticleERROR LOGS ON SEWER CAD 5.5
GUYS,I'M HAVING SOME ISSUES WITH SEWER CAD 5.5, WHILE COMPUTING THE CALCULATIONS, IT GIVES 2 ERROR MESSAGES, "RUNTIME ERROR COPY OF NOT UNDERSTOOD" AND KEY MISSING. PLS NEEDS THIS HELP ASAP.TOLU.
View ArticleRe: Autoplant relationship manager
Hi Abhijit,By design, in Relationship Manager, the lock and unlock options are only active for LineNumber relationships.
View ArticleRe: Supports/Topworks Browser
Hi Phil,Unfortunately, that is logged as a defect against AutoPLANT Piping. The only work-around until that is fixed is to maintain changes locally as you are currently doing.I apologize for the...
View ArticleOpenPlant Isometric Configuration File
I have notice a lot of the settings which where controlled in the style.cfg file have been removed from this file.Particular the setting IE_FMT_COORDLABEL, is there a new location to be able to control...
View ArticleRe: V8i P&ID, Drains and vents : major, minor or utility lines ?
Hello BobCorrect. By design, utility lines are unintelligent. The best way to handle inline components, such as the valves you mentioned, are to place the valves. CATT on them and fill out the desired...
View ArticleRe: Uploading Data sheet to Data Manager
Brianne - I need specific steps for this. Are you linking the Dsheet fields therough the AT view, or the tables ?When you exit the Dsheet editor and the resolve differences dialog appears, which way...
View ArticleAT_CADCOBJECT_EXTRUDE2
Hi All,I am using the at_CADCObject_extrude2, and am finding that I am not able to create an extruded shape with closed ends. I have tried setting the flag parameter to zero, 1 (AT_EXTRUDED_START_RIM),...
View ArticleRe: Uploading Data sheet to Data Manager
I register the datasheet to an AT_tag type in Project Administrator.The cells that are linked are populated with information in the Excel sheet.The columns that have corresponding links in the...
View ArticleRe: EQUIPMENT TANGENT LINE & CENTER LINE REF.IN ISOMETRIC
Thanks for reply, we tried it & its working. However i am getting the dimension from face of connected flange instead of face of equipment nozzle which means it is including gasket thickness which...
View ArticleEQUIPMENT TRIM ISOMETRIC
Dear sir, While extracting trim isometric we are getting number of sheets e.g.fitting connected to different nozzle is extracted in different sheets .We want trim isometric to be extracted in...
View ArticleAutoPlant ss3 win 7 64 bit and XP sharing project
Can someone let me know is there any issue with having an AutoPlant project have both XP stations setup with V8i 32 bit and Win 7 stations setup with v8i 64 bit accessing the same Sql project and...
View ArticleRe: AutoPlant ss3 win 7 64 bit and XP sharing project
You should be fine using this combination of workstations. Just keep the AutoPLANT the same version.