OPIM - Dimension style, text size

Is a way to  change OPIM ISO dimension style, such as text size and arrow shape?Thanks,Maggie

View Article


Image may be NSFW.
Clik here to view.

How to disable prompt while applying Batch process of Autoplant P&ID to OPPID...

Hi,I have made a batch process as per the bentley guidelines for conversion of Autoplant P&ID to OPPID.But I am getting a dialogue prompt Please see below, because of this i need to be on my place...

View Article


proxy enabler for AutoCAD 2015

I have been looking for the correct Bentley proxy enabler for AutoCAD 2015 64 bit, I have down loaded one from your web site and Autodesk but  do not think this is working correctly. is there a way to...

View Article

OPIM - script after converting output from DGN to DWG

When output ISO to DWG format via OPIM, is it possible to run a script right after conversion?The script will do things like zoom extend, purge, or running  a lisp routine. Thanks,Maggie

View Article

Pro_Stahl_3d - need verification on object enabler

I've received a file from a supplier, which contains a lot of proxy objects.We only use Inventor and AutoCAD 2013 in our company - and we need to extract the files, and somehow convert them to...

View Article


proxy objext

Can anyone please explain what is going on here, how can one tell if the enabler is installed correctly on your computer dealing with AutoCAd 2015,  two different people say I should see a tab in the...

View Article

Image may be NSFW.
Clik here to view.

How to add Instrument Tag on Isometric?

When we placed in Orifice Flange set in AutoPPLANT and define the Tag no to that set, it appears on the isometric as shown in fig.But with the same settings, tag no for Paddle Orifice Plate is not...

View Article

AutoPLANT Modeler - Unable to open dcl file

Hello,we have installed Autocad 2014. and AutoPLANT Modeler version 08.11.11.121.Before AutoPLANT Modeler version 08.11.11.121 we want to try AutoPLANT Modeler version 08.11.12.111, but this version...

View Article


Image may be NSFW.
Clik here to view.

OpenPlantIsomatric Manager - Cannot list more than 15 pipelines in browser

I am using OpenPlantIsometrics Manager to configure and test Iso styles, when I open have couple of pipeline/linenumbers, it works great. After I imported an existing model and want to have a wider...

View Article


Image may be NSFW.
Clik here to view.

OpenPlant Orthographics Manager - Some equipments not dimensioning

Hi, i created two pumps from the library and one tank from a solid cylinder (All with intelligence), but when i tried to dimension with orthographic manager only shows the nozzle ID, then i copied two...

View Article

Image may be NSFW.
Clik here to view.

OpenPlant Orthographics Manager - Non Orthogonal Plants (GeoReferenced)

I Tried to get a Layout from non Orthogonal 3Dmodel, because the most of 3D Plant Projects are developed in real positions and the layout must be fixed to the geographical topology, but OPOM cant...

View Article

Is it possible to move Project Roots?

I have my Project Roots setup straight under a Network Root like so,R:\Client1R:\Client2R:\Client3This worked for me once upon a time R Drive was only ever for AutoPLANT projects. I am now starting to...

View Article

Plant Design V8i SS4 - SQL 2014

Good day,We are going to migrate our SQL sevrer, therefore I have a question.Could anyone provide me with information if AutoPlant database can be run on SQL Server 2014 setting compability to SQL 2008...

View Article


How to put Briefcase mode drawings into a access database?

I to save most of all my drawings in Briefcase Mode as the powers that be here couldn't make up their minds on which PLM system they were going to use.Long story short, I need to move my drawings back...

View Article

OPIM - Component selection and connection criteria

When running "Create Iso via OPIM", the component selection window is always set on "All". Can this be set base on user's last use, just like component selection in other command?  Can "Use Project...

View Article


ATDB0718: Relationship Manager Error Code Reported -2147467259

I have an AutoPLANT Equipment model (2012) and when i open the model i get this error:ATDB0718: Relationship Manager error code reported -2147467259At_ArxObjRel.arx: at at_ArxObjRel_addRelInst: The...

View Article

OPIM - Linetype for continued/existing components

The current OPIM use same linetype and same linetype scale for both existing pipe and existing components. If linetype scale is big, existing components do not form a shape in print out; if the...

View Article


Image may be NSFW.
Clik here to view.

OPIM - Component Coordinations output control

Is it a way to control coordination output on components? For some pipelines, it output too many and make ISO image too crowdy. Please see attached image.My guess it most likely occuring on existing...

View Article

Image may be NSFW.
Clik here to view.

OPIM - Tag/Text, Part ID and Coordination

Can Tag/Text, Part ID and coordination output to have seperated leaders? Please see attached image. In this image, Tag, PartID and coordination shared with one leader, and making information block too...

View Article

Image may be NSFW.
Clik here to view.

AP Project Information Differs

Hi,I have created a New Project for OPPID as per given Procedure, But when i opened a new created drawing i get following dialogue box error (See Image 1) I dont know how The drawing gets connected to...

View Article