To and from data : OPPID , spec break
Hello,I am trying to find out to and from data in data manager, in some cases i have been succesful and in some cases its doesnt show any "To and From" information.Suppose, if i use "Spec Break...
View ArticlePrint Open plant specification detailed Report as Row Preview.
Hi,Can I print Open plant specification as a report like in Spec preview in each line of spec.?Preview spec shows me all information I filter from catalogue.This detailed report will be use for cross...
View ArticleOPPID v.427 - Data Manager Connected Line/Equipment Issue
Hello there,Once I place an Instrument in OPPID and then synchronize the PID to Data Manager, this instrument works fine only if it is directly connected to the pipe run or equipment. However, if I...
View ArticleValve Tag Name ERROR
Hi,As a normal procedure of valve numbering in element information, i.e. after putting the Device Type Code - as "V" and Number as for example "2058".It does show correctly in the drawing screen, but...
View ArticleComponent description in 'linenumber' report
Hi, This is regarding extraction of text description in excel file. We are using Bentley AutoPlant- piping. Component description of pipe displays as "PIPE, SCH 160, ASTM A 106 Gr.B PBE" while...
View ArticleWhat TrueType fonts does AutoPLANT (esp. P&ID) install? I want to use ICS and...
What TrueType fonts does AutoPLANT (esp. P&ID) install? I want to use ICS and need to put the fonts on the ICS server. I could not tell by comparing the Window\Fonts folders of the server and my...
View ArticleView Markup Files in OpenPlant
Hi,I am creating markups in Navigator for viewing in OpenPlant. The computers with OpenPlant do not have Navigator installed and the model is not being dispayed in the markup. The model is missing...
View ArticlePressure drop in Piping model
Does Bentley have an application to give the details of pressure drop in Pipe runs in Piping model made from AutoPlant Modeller _SS_5 with Autocad_2012?Could Piping model be used in some Bentley...
View ArticleControl Valves Actuator Orientation in Open Plant PowerPID
Hello,I have attached the image below where i have showed three images as : Image 1, Image 2 & Image 3,As you can see The Images, Can you please suggest me what i should do in class editor, so that...
View ArticleOPM reporting related items with multiple outputs
Hi,I am trying to run a report on my valves and wish to pull the facing property. In this case I am adding the property of pipe_component_has_port, and then the port has a facing vaule. This is fine...
View ArticleFailed to generate iso drawing in OPIM when there is a tap on the pipe with...
In OPM placed a tap one the pipe, then connect to other pipe, the connectivity checker was passed, but iso drawing was failed to generate.
View ArticleNeed to dimensioning to face of flange when connecting to a nozzle.
We just recently upgraded to OPIM Version 08.11.09.458, in this new upgrade I noticed that when connecting to nozzles my dimensions are coming from the weld point between the flange and the pipe. We...
View ArticleAutoplant Annotation tool
Hi, I am looking to annotate a piping GA using the AutoPLANT annotation tool. Question i have on BOP elavation annotation. How do i get it to g on one line rather than have it as two lines.
View ArticleError message for importing CUBE_OPERATOR data via OpenPlant Catalogue
The field "X-OFFSET" can not be changed, can not be removed. It always disapear once add CUBE_OPERATOR EC Class. Version: 08.11.09.440
View ArticleAutoPLANT Isogen mld file
Hi, I am running isogen on autoplant v8i SS4 and my BOM list is not lining up correctly. all the lines are staggered. see attachement. Below is my mld file. How do i get each column to line up with...
View Articleschemas in OPPID SS5
After reading through some of the posts on schemas I am finding there are quite a few that are beneficial to our process, but in trying to change things I am finding that my schemas are named different...
View ArticleOpen plant PID indicates Unhandled Exception error
Hi,I am getting "Unhandled Exception error" on one of my project while placing anything in Oppid.This error is project specific and only for singl user. I have attached snap for more understanding.Same...
View ArticleOPPID Pressure Safety Valve actuator oreintation
Hi ,We are placing Pressre safety valvein openplant PId ss5. If you notice in image attached angle of one of actuator is horizontal and one is vertical.I have tried every angle in the in dialog box but...
View ArticleOpenplant Administration
Hi ,I have two doubt related to openplant administartion.1. How utilise oppid project for the Openplant modeler , weather needs to create separate project folder under workspace for op mpdeler ? or...
View ArticleHow can I enable a new property to display in Insert Field, in ECAnnotation?
Hello everyone, I am having some difficulty trying to achieve what I thought would be a simple bit of customization. I am trying to enable a new property created in Class Editor, to appear in the...
View Article