RE: AUTO PLANT - MASTER NODES
Hello,Thank you for additional information, unfortunately I have been not aware of the Master Nodes. Not sure if there are any significance in them. It could be that they are required as reference...
View ArticleRE: AUTO PLANT - DIMENSIONAL INPUT
I don't think it is necessary to include dash. As well it could be that there is relation to Autocad Units. Are you referring to some drop down list or specification entries?Regards, Artiom
View ArticleRE: OpenPlant - Create Area - Programatically set the parameters
After digging into Bentley dlls with ILSpy and windbg-ing I found a possible solution.It does not open the window for user to set parameters because MyVol has set the property Name.When this is not...
View ArticleRE: AUTO PLANT - MASTER NODES
Yes, I was wanting to understand if there is any use for these nodes. I looks like they are just system required but not used by the designer.
View ArticleRE: AUTO PLANT - DIMENSIONAL INPUT
Nothing specific, but within the program, there are several places that have different entry formats. I believe specifications was one area and equipment and piping was another.
View ArticleRE: Autoplant SPEC Class_Name
Hello Kevin,Generally, the class information in AutoPLANT is stored in Class.ini file. Could you please do elaborate your query.RegardsDinesh
View ArticleAutoplant SPEC Class_Name
Where and how are the autoplant Classes for specs created?Thank you
View Articleautoplant isogen dimensioning
when i run an isometric through isogen which has supports and a tapped branch the diemsnions are not very clear .Please see examples attached. One shows a clear dimension from tapped brach to elbow as...
View ArticleRE: OpenPlant - Create Area - Programatically set the parameters
Hello Aldo,Thanks for sharing the solution here, it might be useful for some other users. I've marked this question as answered. If you have some additional queries do not hesitate to post...
View ArticleOpenPlant - Error "Unable to create a connection using the schema defined in...
Hi,Since yesteraday, I am getting the error below. I reduced it to the follwing line of code:Bentley.ECSystem.Repository.RepositoryConnection c = BMECApi.Instance.Connection;and I also checked that...
View ArticleExport PXF
Hello,I am using AutoPLANT version 08.11.09.140When trying to export to pxf the attached file, I am getting the attache error.Any advice?RegardsAlex
View ArticleSelect Part Number filter
I have two problem on Select Part Number;1) I filter the part number by category but it filter by quantity per unit. (refer attachment for more detail)2) some of the display bar are not show, probably...
View ArticleRE: Autoplant SPEC Class_Name
sorry for the delay....I realize they are stored in the Class.ini, however when creating a new class for a spec you don't simply add it to the INI by hand do you?
View ArticleRE: Autoplant SPEC Class_Name
Hi Kevin,You could add it by hand, or you could use the AutoPLANT Class Editor tool, which simply provides an interface to modify the various INI files etc. involved in the process.Once you define a...
View ArticleRE: Select Part Number filter
That is a known issue, problem 95196, from the Bentley KnowledgeBase (appsnet.bentley.com/.../Default.aspx) and has an easy workaround until the time that the defect is resolved in a future release....
View ArticleRE: Error Message : “FATAL ERROR : Unahandled e0434352h Exception at fe17940dh”
Hello Justinas,I'd like to post, that the same Fatal Error occures directly after the clear installation of AutoPLANT Modeler SS6 (08.11.11.113) also (used Sample_Metric > New DWG > menu Piping...
View ArticleError Message : “FATAL ERROR : Unahandled e0434352h Exception at fe17940dh”
Dear Bentley Team, After going at Piping>Setup>Componenet Preference , we are getting error code for 1 drawing only. Error message : “FATAL ERROR : Unahandled e0434352h Exception at...
View ArticleBentley Instrument and Wiring Issue
Hi,I'm using Bentley Instrument And Wiring V8i. I did the following in Layout DesignerCreate instruments, connect them to Junction Box.Junction Box has two terminal strip ( TB-1 and TB-2). There is...
View Article