Browsing all 4153 articles
Browse latest View live

OpenPlant Modeler SS5-- Flange with PN100

Hi,I want to construct a Flange with PN100 for the pipes DN100, DN150 and DN200..i could not find the PN100 in the specifications !!could anybody tell me how i can add the PN100 to the Data Base ?Thanks

View Article


Open Plant Model Server reference out piping with VBA

I don't know if this is in the correct spot or not so if it needs to be moved le me know.What I am trying to see if it is possible, is within open plant model server inside of Microstation you can...

View Article


AUTO PLANT - WORK AREA REFERENCE FILES

Hello,I am learning Auto Plant V8i and following the Bentley Learn server Plant Design Fundamentals.  I am on the chapter covering Work Areas.  I have set-up a work area and set the reference files and...

View Article

RE: AUTO PLANT-PROJECT FILE ORGANIZATION

Dinesh,So the Regapp tells the database what the object type is and where to place it?

View Article

RE: AUTO PLANT-PROJECT FILE ORGANIZATION

Yes that is correct.

View Article


RE: Troubles with flattener

Hi Dmitry,I have experienced this as well. Are you using flattener with AutoCAD 2012?  In the readme files it states that there are known issues and that flattening should be performed with AutoCAD...

View Article

RE: Export a PXF

I downloaded it and opened in sample Mixed Metric configuration, and it exported without any error.  Try to open it in the sample project or config and see if it has the same error.  If so, I would...

View Article

Secondary Pipe Supports in Bentley Autoplant Piping

Hi,Can anyone tell me how to show secondary strucutural supports in Bentley Autoplant Piping?Like we show 'U' bolts in 3D model and it is also appearing in bill of material list in isometric drawing.

View Article


RE: Troubles with flattener

HiYes, I use AutoCAD 2011. Microstation?.. May be in future...AT_HIDE command gives errorCould not retrieve viewport boundary.Operation aborted.Error status = -5003 current CAD Error message =...

View Article


RE: Export a PXF

Please try to export it 3,4 times. The first time it works but second and third it is not for some reason.I tried what you suggested but still getting the same error in numerous stations.RegardsAlex

View Article

RE: AutoPLANT V8i (SELECTseries 5) has been released!

Hello fross,AutoPLANT V8i (SELECTseries 6) has been released in the middle of June, which is supporting AutoCAD 2014. Please see the following link for more details:...

View Article

RE: Open Plant Model Server reference out piping with VBA

Hello Mark,Could you please explain a bit more on what is it exactly you would try to do. Do you want to have some easy/automated way to reference out all of the pipelines in the server to a model? Or...

View Article

RE: Open Plant Model Server reference out piping with VBA

Justinas,What I am looking to do would to have it reference out all piping related to one system. Then we can make master reference files for each of the systems that can be shared with other...

View Article


Image may be NSFW.
Clik here to view.

RE: Open Plant Model Server reference out piping with VBA

Hmm, and just using higher level of relationship to reference everything from some Unit/Service by just right click on it in the same manner as with pipelines would not accomplish the same goal? You...

View Article

RE: Troubles with flattener

Hmm.. Might want to try to rengerate that viewport.  Another trick I use occasionally is to create a new drawing, reference in all the drawings needed, then right click on a layout and use 'From...

View Article


RE: Export a PXF

I tried 4 times consecutively without error..  I'll have to defer to the Support guys on this one, sorry Alex.

View Article

RE: Export a PXF

Hello Alex,I have also tried to export the PXF from the model attached a few times, and it does not give any error for me in AutoPLANT SS4 version. Could you please describe the issue a bit more for...

View Article


Image may be NSFW.
Clik here to view.

RE: OpenPlant Modeler SS5-- Flange with PN100

Hello Miso,The PN100 rating is not included to a default ratings list in OPM. So, first of all you would need to include it into the RATING_VALUE_MAP class. Open the OpenPlant_3D schema in the Class...

View Article

RE: AUTO PLANT - WORK AREA REFERENCE FILES

Hello,It should work fine that way, strange. Maybe it's for some reason just do not save the settings? Is it the same for all files/work-areas or just with the one file? Can you also see if the dwg...

View Article

RE: Data Manager 'Filter Builder'

Hello Alain,Unfortunately, this functionality is hard coded and there is no way for you to redefine these queries. However, there is already a Defect # D-83179 filed for this issue and it will be...

View Article