Re: Can't Change the Value on field "STYPE" in Catalog Editor
Hi Charlie,As we are using it, STYPE is used to help the system find the appropriate records from your specs. Are you creating a new class for this variable length valve?What I am doing to achieve...
View ArticleOPPID : Class editor warning message
Good morning,Every time I open a supplement xml-file I get several warning messages:<<<2013-02-20 07:55:37,829 [1] WARN - DynamicXmlSerializer (null) -...
View ArticleOP Modeler SS5 : Connect to components in reference file
Modeling EnhancementsSpec reload in active sessionMultiple classes placement from specGridConnect to components in reference fileHi,Does this mean that Mstn can now write to a reference file/model?Or,...
View ArticleRe: OP Modeler SS5 : Connect to components in reference file
Hi DomnicNo, It is just that, active dgn will be able to hold the connectivity information to component in reference dgn. Reference Dgn would remain untouched & cannot be edited.
View ArticleOPPID : custom parametric equipment
Good afternoon,I'm trying to understand how parametric equipment works. When I look at the classes, the all use a .net class called "Bentley.Plant.Application.Pid.Catalog.EquipmentParametric" but the...
View ArticleRe: OPPID : Class editor warning message
Hello Wim Aerts,I have checked withe the develpment team for Class Editor and here is what I have received back.This is generally caused by a custom attribute whose class definition has had a a...
View ArticleSloped lines
Could anyone please explain how to create a sloped line in Piping? I'm using V8i, SS4. Thanks in advance!
View ArticleRe: OPPID : Class editor warning message
Hi Tony,Thanks, it 's reassuring that the messages will not interfere with the functioning of the application. It would be great though if they could implement a more elaborate description in future...
View ArticleRe: programming on autolisp
i found main function which is base of "at_ComponentIDList_selectFromCurrDocument", is it ssget and it is what i need.
View Articlecomponent preferences in feild "main size" shows values 2 4 and 6
Good day!My component preferences in feild "main size" shows values 2 4 and 6 instead of 100mm, 150mm etcWhere should i find the heart of problem?Reset autoplant and comp is not helpful.
View ArticleRe: component preferences in feild "main size" shows values 2 4 and 6
Having 2, 4, and 6 in the main size may be indicating 2 issues here. One only imperial and Mixed Metric projects show values such as 2, 4, and 6 in the main size. So the project in use may be an...
View ArticleRe: component preferences in feild "main size" shows values 2 4 and 6
Yeah, i had already solved this problem, the second variant is suitable. Thanks)
View ArticleRe: OPPID : custom parametric equipment
Please see if this wiki helpscommunities.bentley.com/.../4487.aspx
View ArticleSubtracting Solids
Hello All,I am seeing that AutoPLANT scripts are capable of extruding to produce a solid, but I am not able to find a method which will permit subtracting one solid from another. Am I overlooking a...
View ArticlePSDS 08.09.04.63 How do I convert Column Line Reference data into Metric Units?
All the information on the isometric is in millimeters except the column line refence information. I have tried updating the psiso.lib. Verifying design file units, jsm units and clinrefm.dat units all...
View ArticleSupports/Topworks Browser
Hi All,Has anybody had luck modifying the supports/topworks browser (content) in AutoPLANT V8i? We maintain our settings and projects on a server, and for whatever reason, the supports/topworks browser...
View ArticleOPPID - converting fittings
Good morning,I am still strugling to get my project on rails. Latest issue is the conversion of fittings from plantspace PID to PowerPid.We have object from plantspace pid named "FITT_REDUCER". I have...
View ArticleRe: OPPID - converting fittings
Good evening,Some update:I have tested with another fitting and I think that the problem lies in the relationship "RUN_HAS_IN_RUN" that is not formed, although it is defined in the jsm conversion class...
View ArticleOPPID SS4 - Valves disconnecting from Pipeline
We are having issues with Valves disconnecting from Pipelines we suspect revisions but are not sure. The only way we see the disconnects is viewing in DataManager Valve List there we see the disconnect...
View Article