Quantcast
Channel: OpenPlant | AutoPLANT Forum - Recent Threads
Browsing all 4153 articles
Browse latest View live

RE: What is the Bentley Passport & Navigator features uses for our designer?

Dear Bentley,Currently we are using Naviswork to view our models.Then is it needed to have this navigator/passport ?By ignoring these features while purchasing, will it affect us?

View Article


RE: What is the Bentley Passport & Navigator features uses for our designer?

A passport is required for different Bentley products as described. If you don't want to use one of them you don't need them.On the other hand passport pricing is fortunate - thats why some large...

View Article


What is the Bentley Passport & Navigator features uses for our designer?

Dear Bentley Family,What is the 'Bentley Navigator' and 'Bentley Passport' features,shown in the attached screenshot.?What & where is the use of it for our designer/end users?Is it free features or...

View Article

RE: Valve body not displaying with certain Tagging (NAME) Convention??

Justinas and Melissa,Note that in the parser expression when there is a literal character between two properties you can use the [?\w]*. There is no need to use the number of characters. The system...

View Article

RE: Valve body not displaying with certain Tagging (NAME) Convention??

Yes, that's true Tony, but sometimes having a more strict rule is also good :)

View Article


RE: Valve body not displaying with certain Tagging (NAME) Convention??

Thank you Tony. I in the end had to use [?\w]* anyway in my Parser Regular Expression instead of [?\w{4}]. As when editing any properties after placing the valve it scrambled up my Tag Number, but with...

View Article

RE: OpenPlant Specification Generator - Converting from PSDS spec/catalog

Hello,Please also review the new article I've just added on how you can convert your PSDS catalogs/specs to OpenPlant format using Exchange software here:...

View Article

RE: Data Manager - Specsheet with AT_INST - Mismatch

Eric,The differences you are seeing is caused by the way the Datasheet Module's coding structure formats that "Available Fields List".  It shows all fields in the Doc_Reg table (this is for Datasheet...

View Article


Image may be NSFW.
Clik here to view.

RE: Bentley Instrument and Wiring - Create Multiple Cable and Terminal

Eric,I understand your situation and believe have found a suitable solution for you.  Please follow the steps below:Please make sure that you already have your custom Loop Standards defined.  We will...

View Article


Bentley Instrument and Wiring - Create Multiple Cable and Terminal

I've used Instrument and Wiring for a few projects.  So far, my experience is good using this software.  I've also took 1 week course on Bentley I & W.  Here what we learned during course :Design...

View Article

RE: AutoPLANT import .XML and .PID (ISO 15926) format from SP P&ID

Hello Packin31,Can you provide a bit more details?  What type of data are you referring to?Thank you,Brandon Moberg

View Article

RE: AutoPLANT import .XML and .PID (ISO 15926) format from SP P&ID

Hi Brandon,Been awhile since we have chated. Hope all is well with you.They were evaluating SP P&ID in another group and they said that SP P&ID exports out .XML for data and .PID format for...

View Article

AutoPLANT import .XML and .PID (ISO 15926) format from SP P&ID

Have read a few threads on this but there was no definitive answersCan AutoPLANT V8i ss4 import .XML data?How can we open a .PID formatted drawings?Thanks

View Article


RE: B3D_SYSTEM_UNITS & B3D_UORS_PER_SYSTEM_UNIT in PSDS XM

I changed the projdefe.rul & the Db to 12000 OURS per FOOT to match the design file.  I got properly sized pipe; however, if I place pipe with insulation, the insulation comes in 12x too thick.For...

View Article

Image may be NSFW.
Clik here to view.

RE: Data Manager - Specsheet with AT_INST - Mismatch

Hi Brandon,Thank you for the detailed explanation.  I tried to modify the AT_INST view in Project Administrator, but like I said, the fields there doesn't correspond to the one found in the Datasheet...

View Article


Data Manager - Specsheet with AT_INST - Mismatch

 I want to add some linked field (from Process Table) on specsheet.   I know I have to modify the AT_View ( in this case AT_INST) in order to add these fields.   But there are fields mismatch between...

View Article

Is anyone using SYSTEM in OPM?

We are trying to get the System property/relationship working in OPM for process and associated component tagging, but so far have been met with little more than pain.The property seems to work okay...

View Article


RE: Data Manager - Specsheet with AT_INST - Mismatch

Hi Eric,There is an existing post that you might already read. communities.bentley.com/.../how-do-i-add-custom-fields-in-the-datasheet-field-list.aspxFrom this post:DOC_REG:  All Tags will have this...

View Article

RE: Lack of Support from Support

My impression is that who ever looks into a ticket he doesn't care if it is urgent or not.What is the point of having a quick reply directing me to read a previous thread or just telling me to read the...

View Article

RE: Lack of Support from Support

Depending on the issue  the borders between training, support and consulting are floating. These areas are depending on each other and one will not replace the other. I agree that support would...

View Article
Browsing all 4153 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>