hi, i using autoplant v8i ss3 and I would like to add a barcode to my isometrics when i run them through isogen. I can add the field I want to the POS file to get it to come out in the right position...

View Article


RE: Autoplant hand valves tag prompt/dialog

Hello Ken, It seems this should be quite possible.  Valve input routine should be changed. I would recommend using input routine for control valves as example modules\base\common\cntinput.ebs. Default...

View Article


OPM Schema Parser Expression

Good day,Our pipeline specifications are a 4 or 5 character set where XX#XO is the format.X – any capital alpha# - any single digitO – optional capital alpha dependent if threaded. In OP3D schema...

View Article

RE: Autoplant hand valves tag prompt/dialog

Which application are you referring to?  AutoPLANT P&ID or AutoPLANT Piping?

View Article

Expport to PDMS

How can I export models created with bentley Autoplant so they could be opened with PDMS. I am trying to export with STEP files in AutoCad but it is not showing good.

View Article


RE: Expport to PDMS

Hi,We are also interested to export Autoplant 3d drawing to PDMS.Is any way or tool available to export Autoplant 3d drawing to PDMS.Waiting for reply. 

View Article

RE: Bentley Piping Database Error

Hi bfullenkamp,Your solution not working!

View Article

Bentley Piping Database Error

When I load a certain Piping model, I am getting the error message:  Database Error ATDB:  SQL Error State: 07002, Native Error Code: -3010, ODBC Error: [Microsoft][ODBC Microsoft Access Driver] Too...

View Article


Autoplant SS3 SQL server version supported?

Hi,Could somebody confirm whether the Autoplant SS3  would work on SQL server 2012 (currently running on SQL 2008) ?Thanks,Adam

View Article


RE: Autoplant SS3 SQL server version supported?

Correct. SS3 supports up to SQL server 08.

View Article

RE: How To Creating And Configuring SQL Server based Database/Project in...

Dinesh is correct. What he provided are the steps to create a SQL server datasource. Once that is done, I would use project Packager to package your Access based projects and unpackage them to the new...

View Article

How To Creating And Configuring SQL Server based Database/Project in...

HI Bentley Family,We are using Microsoft Access Database from quite a few years, now we are thinking to create a database in SQL SERVER 2008 R2 or SQL Express Server 2005 for Planrspace design series...

View Article

Component Preferences

Hello,I'm using AutoPLANT Piping SS4 on AutoCAD 2012.Do you have any document that explains the options we have ander result field? Please see the attached file.Looking forward hearing from you.Alex...

View Article


Image may be NSFW.
Clik here to view.

RE: Component Preferences

Hi Alex,Please browse to your %ProjectRoot%Config% and open CompPref.ini file. Here, you will find description of this fields. Hope this helps !

View Article

Image may be NSFW.
Clik here to view.

RE: Connection Between Plastic and Carbon Steel

Hi Alex,I think the issue is that your plastic spec is still using standard socketweld end conditions.  Instead of using SWF, you should use the socketweld end conditions created for use with the...

View Article


Connection Between Plastic and Carbon Steel

Hello,I'm using AutoPLANT version SS4 on AuotCAD 2012.Please see the attached file. There are 2 specs (plastic and carbon steel) and a screenshot.I'm building the following model: 2" Elbow 90 from spec...

View Article

Image may be NSFW.
Clik here to view.

AP report generator not accepting change to report file

AutoCAD 2012; AutoPLANT V8i SS4 (08.11.09.175)Just wanted to report a minor bug.  When you are cofiguring a report in the AutoPLANT PDW Report Generator, it is not possible to change the RPT file that...

View Article


RE: Openplant Manager Connection problem

What version of openplant is being used?

View Article

OPM Bolts and Gaskets: How to control them

We are seeing a number of issues in our models where OPM will control what line/spec bolts and gaskets are associated with where the joint is at a line change or spec break.  The modeler needs to be...

View Article

RE: Openplant Manager Connection problem

Bentley Openplant Modeler v8i (SELECT Series 3)  V.08.11.08.311

View Article
Browsing all 4153 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>