Re: Error TopWorks when generating ISOGEN (Proj. upgraded from xm to V8i)
I am experiencing similar errors with topworks in my upgrade testing from AP V8i SS1 to SS4. Guess it should be a service ticket if it's not an isolated issue. Are you using any customized scripts??...
View ArticleRe: Error TopWorks when generating ISOGEN (Proj. upgraded from xm to V8i)
In my case, I has a customized OPCFHDR in the project. You will need to compare it to the updated version shipped with AutoPLANT and make sure it contains all the new values for jacketed pipe etc....
View ArticleRe: Error TopWorks when generating ISOGEN (Proj. upgraded from xm to V8i)
I have a customized OPCFHDR file, going to check the difference with an updated version in V8i.I've created a new project also in an earlier stage with V8i SS3, and there I only have problems with...
View ArticlePiping MTO with Line No. & Spec. at time.
hi,Can anybody help me to extract Piping MTO with Line No. & Spec. at time.Thanks in advance.Shrinivas
View ArticleRe: OpenPlant Problems with Equipment & Nozzle Naming/Numbering
1. I think this is a known issue. You can however move a singel equipment with its handlebars. But would be great to be able to move components with regular microstation move command. Especially...
View ArticleRe: OpenPlant Problems with Equipment & Nozzle Naming/Numbering
1. Moving the equipment would not cause equipment number to change2. again, modifying an equipment should not cause and tag number change.It seems like tagging schema is not setup correctly which is...
View ArticleRe: OpenPlant Problems with Equipment & Nozzle Naming/Numbering
Prashant. Do u mean that moving equipment should be working when using regular microstation move command?
View ArticleRe: Error TopWorks when generating ISOGEN (Proj. upgraded from xm to V8i)
Yea I'd be willing to lay the blame on the HDR file... As for the specs, I've never heard of such a thing? Maybe try turning off the dynamic filtering and double check your access rights to the...
View ArticleRe: Error TopWorks when generating ISOGEN (Proj. upgraded from xm to V8i)
Might try checking the project's config.ini...from AutoPLANT readme: Legacy projects that access catalogs and spec in the Program Files folder will need the following line modifying in...
View ArticleRe: Error TopWorks when generating ISOGEN (Proj. upgraded from xm to V8i)
When I remove the Topworks, the ISO is generated... Still searching. The strange thing is, a complete new environment created with V8i (so not updated) had only problems with the topworks like...
View ArticleAutoPLANT v8i SS3 install constantly failing
Hi forum, On an WindowsXP sp3 with 2G RAM x86 machine, I have AutoCAD 2010 update 2. Trying to install AutoPLANT v8i SS3 I constantly fail at the begining, just after selecting components and clicking...
View ArticleRe: AutoPLANT v8i SS3 install constantly failing
Have you launched AutoCAD yet. I had the same issue and that's how mine got resolved.
View ArticleRe: OpenPlant Problems with Equipment & Nozzle Naming/Numbering
Jojje thank you for your reply.Modifing any data related piece of information associated with the nozzle has caused this problem.Are system is typically out of the box with a few minor changes in the...
View ArticleRe: OpenPlant Problems with Equipment & Nozzle Naming/Numbering
Prashant we have moved the equipment via microstaion commands and this has caused us problems. We will start to move the equipment only by its grips to see if this overcomes our problem.The tagging...
View ArticleRe: AutoPLANT v8i SS3 install constantly failing
Thanks and yes... and no luck.I had also tried with SS4 and I have EXACTLY the same issue.The only combination that worked was with SS2. But that doesn't satisfy me.
View ArticleMicrosoft Ofice 2013 compatibility with Autoplant V8i
Hi All,Has anybody had proven success with operation of AutoPlant v8i with Microsoft Office 2013. We have recently purcheased AutoPlant Design V8i (Select Series 4) and AutoPlant P&ID. We require...
View ArticleRe: OpenPlant Problems with Equipment & Nozzle Naming/Numbering
May be you should move onto latest priority build of OPM. There is also going to be new release of OPM very soon. Please contact your Bentley representative about these builds or Bentley TSG.
View ArticleRe: OpenPlant Problems with Equipment & Nozzle Naming/Numbering
Prashant we are currently using 08.11.08.311 which I thought was the latest priority build.
View ArticleRe: AutoPLANT v8i SS3 install constantly failing
I know in previous versions there have been issues with users who have installed and uninstalled Autodesk products on their machines in the past. Sometimes noise is left in the registry that kills...
View ArticleRe: OpenPlant Problems with Equipment & Nozzle Naming/Numbering
That was the last commercial release. Prashant is referring to subsequent builds provided to resolve specific issues on user sites. Log a ticket with TSG they can give you more details.
View Article