Quantcast
Channel: OpenPlant | AutoPLANT Forum - Recent Threads
Browsing all 4153 articles
Browse latest View live

RE: OPM without OPMS in a distributed environment

Shaun"new release of OPM coming in the next few days"....do u have a estimated date?Im about to upgrade to "08.11.09.383" but if a new version is coming in the next few days I think I will wait for the...

View Article


RE: OPM without OPMS in a distributed environment

Parijat,We are in the process of building a true Project Database. This will replace all of our current plant databases and allow us to share data between 2D and 3D. Any information added in either...

View Article


RE: OPM without OPMS in a distributed environment

Jojje,The development teams are in their final tests on all of the new OpenPlant products. As for the exact date, I will have to leave that to the developers, I would not want to tie them to a date. My...

View Article

RE: AutoPlant Isogen error when connected to Equipment Nozzle

So it's either as Isogen issue, in which case there aren't too many good solutions), or its a difference between SS3 and SS4.I would compare the PCF out routines (ebs files found in the...

View Article

RE: Bentley SpecGen - Specification Generator - Slow loading on Rebuild

Try to load the spec in access and perform a compact and repair.  Compare the size of the spec before and after.  If it goes down significantly, than you had alot of erroneous data left in the...

View Article


RE: AutoPlant Isogen error when connected to Equipment Nozzle

Thanks Jesse,That would work if it was one model but I have 25 designers using 400 models across two countries so would not be workable. I have checked the pcf out files but I copied over the ones from...

View Article

RE: Bentley SpecGen - Specification Generator - Slow loading on Rebuild

I've opened the spec many times before in Access and used the Compact/Repair tool to help reduce the size etc but the size only goes down 1 KB. Also this issue is still the same after the tool is done....

View Article

Bentley SpecGen - Specification Generator - Slow loading on Rebuild

Hello,I use Bentley Specification Generator V8i (SELECT series 3) or SpecGen for short.In the SpecGen program. I copied a template Spec in my Project. In the Spec itself; I edited the tables to filter...

View Article


RE: Bentley Autoplant V8i PDS

Hi Glen,We are looking to see if it is possible to convert from PDS to Autoplant. Has there been any update since this post?RegardsKen

View Article


Bentley Autoplant V8i PDS

Hi folks,I need some information please.Starting a project in Bentley Autoplant V8i soon. The client will be sending some models previously designed in PDS format.1. Is it possible to import PDS models...

View Article

RE: OPM without OPMS in a distributed environment

Shaun,The true Project Database idea to share data between 2D and 3D is really fantastic. The PlantSpace industry has been waiting for a long time to see this work. Thank you for the good news!

View Article

OpenPlant Isometrics pipeline not running inline with Plant North

Hi AllI have a question that I hope someone can answer.We are runnin lines that are not north-south or east-west. The plants orientation has been rotated 32 degrees from North. Its all fine when...

View Article

RE: OPM without OPMS in a distributed environment

ShuanWe are also about to upgrade to 08.11.09.383 over the weekend. Are you able to confirm a release data with the developers. Everytime we have upgraded it has been an involved process. I would hate...

View Article


RE: OPM without OPMS in a distributed environment

Hello Richard,The build Shaun is talking about will not be available in the official SELECT downloads site, as it will be handed out as a Priority build for OPM / OPIM / OPMS products. It will have a...

View Article

RE: GAS drawing takes approx. 30min to 1 hour for just ploting preview and...

Hello,Thank you for the suggestion Jesse, unfortunately not the case. The xrefs are referenced as Attachments, but there were no  difference in plot preview performance after reattaching xrefs as...

View Article


RE: AutoPlant Isogen error when connected to Equipment Nozzle

Hello Ken, Thank you for details. Could you please check if project root has  Modules\%ModuleName%\xchg\pcf folder ? In case if pcf ebs out files are located on project level AutoPlant will use them in...

View Article

RE: OPM without OPMS in a distributed environment

Hi Justinas,We just upgrated our PW (.574) and OPM to the latest version (.383). If we upgrade OpenPlant modeler into this coming version, do we have to upgrade PW too?I would like to also have a list...

View Article


RE: OPM without OPMS in a distributed environment

Pekoll,No, you would not need to upgrade ProjectWise, latest OpenPlant buils will be working with the same PW builds as the 383 version is.As regarding fix / feature list, please let me see if I can...

View Article

RE: how to automate i model composer-Navigator session

Lealg2000,As far as I know, at the moment there is no other way to automate i-model creation / refresh, than using the ProjectWise Orchestration Framework/Automation Service. More details regarding PW...

View Article

RE: AutoPlant Isogen error when connected to Equipment Nozzle

Hi Artiom,Appreciate your help. Yes the directory is present. Funny thing is this is working on a spare XP machine we have but is not on all the PC's we have upgraded to Win7.  We are using version...

View Article
Browsing all 4153 articles
Browse latest View live