Specs in external databases
Windows 7 EnterpriseAutoCAD 2012 x64AutoPLANT V8i SS4 x64Hi Everyone,I am experimenting with moving specs from MDB to storing them in a central SQL db instead. So far so good, with only one minor...
View ArticleRE: Database Error in Crystal Reports (Generating BOM)
Good day. This is snapshot of error about enough memory.Seems to me It's happened not only in big drawings.
View ArticleDatabase Error in Crystal Reports (Generating BOM)
Good day.When i try generate Bill Of Materials i get error two times:Seagate Crystal Reports: Database ErrorError opening file.File could not be found: 'Piping', at file location 'Piping'And table of...
View ArticleRE: Database Error in Crystal Reports (Generating BOM)
Maybe problem is version of Crystal Reports. I have Autoplant ss1. What version CR should i have?
View ArticleMaster Spec Folder
Hello,I'm using AutoPLANT SS4 on AutoCAD 2012.Is there a way to define a new Master Spec Folder for each new project that I open?right now the default path for each new project is...
View ArticleRE: Master Spec Folder
Hi Alex,Instead of using the "New Project" to create our projects, we typically create a configuration that contains the settings we need then drag that configuration over a project root to copy all of...
View ArticleRE: AutoPLANT Piping file - units
Hi Alex,If you are referring to units precision, this is stored in the Units.ini file found in two placesIn the installation at C:\Program Files (x86)\Bentley\Plant V8i\ConfigAnd in the project at...
View ArticleAutoPLANT Piping file - units
Hello,I'm using AutoPLANT SS4 on AutoCAD 2012.When I open a new piping file or an existing file (and save it later), I see (in AutoCAD command - units) that the precision is 0.How can make the...
View ArticleRE: document id
Do you get this error opening a drawing? Try the following:1. Copy the drawing to a temp folder.2. Using Relationship Manager, delete the drawing from the project.3. Using Relationship Manager, pick...
View ArticleRE: document id
If you are talking about the "Document ID is Null" error, while creating a new document in Document Manager (image attached), than it is most likely caused because your Windows user group Users does...
View ArticleRE: Specs in external databases
Hello Jesse,Thanks for reporting this issue to us. I have filed a Trouble Report# D-130277 regarding it, so it will be reviewed by the development group.Also, I have created a SR linked to the TR on...
View ArticleOpenPlant Modeler Administrator Training - Complaint
Just wondering if any else is running into this problem.We have been using OpenPlant Modeler SS3 and SS5 for sometime now and are very unsatisfied with the out of the boxcomponents and pipes. They work...
View ArticleRE: OpenPlant Modeler Administrator Training - Complaint
Hello AndrewH and cswnow,I work for a company with same characteristic of yours. We are using OPM SS5 and we are having good results despite some problems.We can help you with OPM administration if you...
View ArticleRE: Database Error in Crystal Reports (Generating BOM)
Is this happening on same machine? Could you once again try recreate process monitor log. This time it should include Crystal Reports related files. Please use above manual to create log and include...
View ArticleRE: how to automate i model composer-Navigator session
Could you please elaborate a bit more, on what would you like to automate? Is it i-model creation/updating on some scheduled basis? Or do you need some other behavior? Looking forward for some addition...
View Articlehow to automate i model composer-Navigator session
I would like to know where to find information on how to automate the process of updating the Navigator session. thanks in advance
View Article