Quantcast
Channel: OpenPlant | AutoPLANT Forum - Recent Threads
Browsing all 4153 articles
Browse latest View live

Re: Insulation Linetype

Line type can be changed by Opening Project Administrator> Piping>Preferences>Line Type

View Article


Image may be NSFW.
Clik here to view.

Re: Model file name sent to Isogen pcf file

Hello Here is one of the way. This is a function that should be added to opcfhdr.ebs'//'// Function to write drawing name'//Public Function PCF_DRAWING_NAME(indentFlag As Integer) As Integer  Dim nStat...

View Article


Re: Model file name sent to Isogen pcf file

Thank You! It works perfect! I modified it slightly to give it an attribute number that I could place on the output drawing with the .pos file. There maybe another or better way to get it on the...

View Article

Re: AutoPLANT V8i (SELECTseries 5) has been released!

Hello Henrik,In AutoPLANT SS5 release supported AutoCAD versions are the same as in previous SS4 release. It's AutoCAD 2012. From the readme:AutoCADAutoCAD 2012 + Service Pack 2 (64-bit &...

View Article

Re: AutoPLANT V8i (SELECTseries 5) has been released!

Just in case link to AutoPlant Modeler SS5 read me file:ftp.bentley.com/.../readme.htmRegrads,Artiom

View Article


Launching Prosteel ruins workspace/profile

Windows 7 EnterpriseAutoCAD 2012AutoPLANT V8i SS4Prosteel V8i SS5 for AutoCAD Hello!I was tasked with investigating RWA files as a tool for interdiscipline referencing and composite model creation.  As...

View Article

Re: Launching Prosteel ruins workspace/profile

Hello Jesse, Not sure if it is related but according to AutoPlant SS4 Read Me Prosteel V8i SS5 is not supported. I will setup a test environment and run a couple of tests. Will let you know further...

View Article

Color By Service in AutoPLANT Piping

Hello, I am using AutoPLANT SS4 on AutoCAD 2012.In an AutoPLANT Piping model I change the color to be by service in the drawing preferences.I defined the service color in the color.ini file in 2...

View Article


Text Rotate on Equipment OPPID

Would this be possible?? When rotating my equipment I need the text to stay 'upright'. ?? 

View Article


Re: AutoPLANT V8i (SELECTseries 5) has been released!

Thanks JustinasL and Artiom J,Now I realize that the reason why I could not find the information in the readme file was that it was stated as new in SS4... But thanks for enlightening me :)RegardsHenrik

View Article

Re: Text Rotate on Equipment OPPID

Melissa R,Currently there is no way for text to remian "upright" in a cell without some vba programming. You can set up PowerPID to make the "M" a default property and have the system attach the "M" to...

View Article

Re: Color By Service in AutoPLANT Piping

Hello Alex, From Piping Help file: The color table is initialized by reading COLOR.INI and the values are stored in the ACAD dictionary. As new values are found they are added to the dictionary.These...

View Article

Re: Text Rotate on Equipment OPPID

Thank you very much, I have changed it that the text is inserted as an annotative property.

View Article


Drawing Flattener cannot load DWG layouts with custom names

Windows 7 EnterpriseAutoCAD 2012AutoPLANT V8i SS4Hi All,Not sure if this has been reported before, but it seems like Drawing Flattener will error when loading a DWG whose layouts have been named...

View Article

Closed

Post to be deleted ... but don't know how :S

View Article


Export component collection

Good morning!I am trying to develop a couple collection based on components which are to be exported through the PCF process, and need to be able to identify how AutoPLANT is either creating or...

View Article

Re: AutoPLANT V8i (SELECTseries 5) has been released!

Respected Bentley Team,Please have a small look on following link first :communities.bentley.com/.../263219.aspxWant to know how ss5 will boost the execution performance of any project compare to...

View Article


Detail Sketches on Isometrics

Hello Everyone,I want to have three different details of Supports to be generated on Extracted isometrics , i have gone through the Detail Sketches.PPT provided with Autoplant Isogen in C:\Program...

View Article

AutoPLANT Object Enabler - FATAL ERROR

We are trying to setup Win7 computers with the AutoPLANT Object Enabler so that folks without the full AutoPLANT software can properly view drawings containing AuotPLANT objects.When we try to open the...

View Article

Re: AutoPLANT Object Enabler - FATAL ERROR

Hello,Is this happening to any model you are trying to open? Do you have service pack 2 for Auto Cad installed on your PC? I will try to run a couple of test on my side within similar environment. Just...

View Article
Browsing all 4153 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>