Quantcast
Channel: OpenPlant | AutoPLANT Forum - Recent Threads
Browsing all 4153 articles
Browse latest View live

Re: How do we Bulk load company standard services into OPM SS5 and make level...

Hello Parijat,1. Could you explain a bit more, what kind of batch loading you would need? Is it just one time operation, when you would like to load a full list of your services to OPM and check it to...

View Article


Re: How do we Bulk load company standard services into OPM SS5 and make level...

Hi Justinas, When I say bulk import OPM services - I am talking about a new feature of importing services through text file, this feature - Import project objects (Unit, Service) through text file is...

View Article


Image may be NSFW.
Clik here to view.

isogen not using custom skey for dummy legs

Hello!(AutoPLANT V8i SS4, AutoCAD 2012, SQL 2008)I am having an issue where isogen ignores the custom symbol I have created for dummy legs.  In the image on the left below, you will see the expected...

View Article

Image may be NSFW.
Clik here to view.

Re: How do we Bulk load company standard services into OPM SS5 and make level...

Hello Parijat,I have created a knowledge entry on how to use that new  import feature in OPM SS5. You can find it here: communities.bentley.com/.../8569.aspxPlease, let me know if it is clear enough...

View Article

Re: OPPID Data in AutoCAD

Is there something specific Navigator needs to point to when opening i.dgn files published out of OPPID?  I noticed that there are times when the items list is populated, other times where it's only...

View Article


V8i ss3 P&ID settings.dbf to ss4 format db3

Now that we have upgraded from V8i ss3 to ss4. How do we convert the P&ID settings.dbf to the new ss4 format (db3)

View Article

Re: OPPID Data in AutoCAD

Sorry a little more here...I noticed that the i.dgn is empty even when opened back in OPPID.  I tried a new blank file, placed some pipelines and valves, published an I-model and it was good.  SO, back...

View Article

Re: V8i ss3 P&ID settings.dbf to ss4 format db3

Please do upgrade the project first.1.Open Project Administrator enable Integrity Check in the Edit>Preferences dialog.  2. It should run automatically, but if not right click on the project and...

View Article


Error when opening drawing

When I open a drawing containing a ferrule and a length of pipe, I get the following error message:"Command: Error: PUTL0403: AT_TRI_FERRULE requires a traversal"What does this mean?

View Article


OpenPlant Modeler SS5 scans all attached reference files when modeling i.e....

Hi,I am using OPM SS5 (08.11.09.278) with or without ProjectWise.When I click for instance 90 deg elbow command, OPM starts loading all reference file (simple 3d mstn files made with latest v8i...

View Article

Re: OPPID Data in AutoCAD

Brent,First - modify the PID.cfg file by locating the section below and editing it to include the OpenPlant_PID schema.#Specify schemas that are to be used for Publish...

View Article

Re: V8i ss3 P&ID settings.dbf to ss4 format db3

Dinesh,Thanks for the reply. We have run Integrity Check on the projects.I think we are not talking about the right file here.We are looking to use the ss3 settings.dbf  for P&ID from...

View Article

Re: How do we Bulk load company standard services into OPM SS5 and make level...

Justinas, Thank you very much for creating a knowledge entry on how to use that new  import feature in OPM SS5, I am sure it will help a lot of people. The sample files that you sent did work for me...

View Article


Re: OPPID Data in AutoCAD

Thanks Tony...much closer as I'm now seeing all the data being published except for Major and Minor pipeline (from my test file).  I'm still getting two errors as shown below.  I will keep...

View Article

Document Manager issue

I had both Autocad 2008 and a trial version of Autocad 2012 installed. I un-installed 2012 and when I try to open a piping drawing from Document Manager now, nothing happens. Before the un-install, it...

View Article


Re: Document Manager issue

Hello,Edit AT.ini (Win XP C:\Documents and Settings\All Users\Application Data\Bentley\Plant V8i\CFG and Win7 C:\ProgramData\Bentley\Plant V8i\CFGChange CADAPP variable in all sections so it would...

View Article

Re: isogen not using custom skey for dummy legs

Hello Jesse, Could you please upload related files. Have you creed new skey for  AT_SUPPORT_DUMMY or edited default one ? If new, what parent symbol was used?Have you tried to compare PCF from...

View Article


Re: Error when opening drawing

Hello, I have not seen this before. Could you please send files for testing ? As well please let me know what AutoPlant version is used. Is this is complete  drawing specific? Or it is possible to...

View Article

Re: Error when opening drawing

I'm sorry but it does not happen now! It seems to be ok.Tom

View Article

Re: Document Manager issue

Just to add, I'm not sure which version of AutoPLANT are you using, but if it's the latest version, than it is only supported to be running with AutoCAD 2012. If it's AutoPLANT SS3 release, than...

View Article
Browsing all 4153 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>