German language pack for Openplant CE Update 10
Hello!When will be available german language pack for OpenPlant Connect Edition Update 10?Thanks in advance.
View ArticleChanging Presentation & Transperency of individual attached model files in...
Hello All, I am trying to change presentation & transparency of individual attached model files in Reference. But it's not happening. Kindly help to advise. Thanks Regards, Thiha
View Article3D Cable Solid Problem
Hi, when I visualize a cable successfully connected it showed me a correct route, but when I create a 3d cable solid the cable doesn't follow the same route. The cable go throught raceway and came back.
View ArticleAutoPLANT support POD
does AutoPLANT support POD format of Bentley?or laser scan supporting format ?
View ArticleSQL Server Connection Failed (OPPID V8i)
Hello All, For OPPID (V8i) database migration to SQL server, I loaded SQL Server Management Studio and tried to connect the server "W10-OPM-U9-DS" as per the instruction given. Used the given username...
View ArticleProstructure file While I extract the i.dgn file through Autoplant composer
Pro structure - Version 08.11.11.207Object enabler version: pstoe081111207enWhile I extract the i.dgn file through Autoplant composer I get the error, that all objects are going to the corner...
View Articlei.dgn file through Autoplant composer I get the error
Pro structure - Version 08.11.11.207 Object enabler version: pstoe081111207enWhile I extract the i.dgn file through Autoplant composer I get the error, that all objects are going to the corner location...
View ArticleCustom Cells not moving when selecting the move command
I'm finding with several of the custom cells we have created in OPPID, when modifying the drawing those cells don't move (either when stretching or moving). Any ideas why?
View ArticleError 59054
Has anyone reslved this error? The message goes like:Error moving component. An existing connection was closed by the remote host.Thanks.
View ArticleWhat version of Access is compatible with OpenPlant Specification Generator
What version of Access is compatible with OpenPlant Specification Generator 10.10.00.72 receiving error "Access Database Engine is not installed : Microsoft.ACE.OLEDB.12.0 not found" Access opens fine...
View ArticleAutoplant: Updating component on slip-in flange (redraw component checked),...
When we are trying to change line number of a line, slip-on flanges are graphics are also changing. This also happens when you update anything in update component, not just line number, as long as you...
View ArticleHow to create a new 2D display fragment in BRCM
How to create a new 2D display fragment in BRCM for equipment? I create two elements and they do not work correctly, they are inserted from the same point
View ArticleOP ModelServer replaced by PlantSight?
Saw the recent coffee corner where checking out and referencing itwins was demonstrated.Looks great. Does this mean that op model server is now redundant?Also, there was a brief mention of file versus...
View ArticleOP ModelServer replaced by PlantSight?
Saw the recent coffee corner where checking out and referencing itwins was demonstrated.Looks great. Does this mean that op model server is now redundant?Also, there was a brief mention of file versus...
View ArticleHow can I change the port when inserting a pipe class PIPE
Hi,Can you please tell me if it is possible to change the PORT of a pipe insert (PIPE class) when placed in the model? By default the program inserts the PIPE class via MAIN_PORT, can I set it up so...
View ArticleDoes anyone knows if the Bentley Plantflow pressure drop calculations...
I am looking for a software that can generate pressure drop calculations for networks importing data from 3D piping CAD software directly, not using PCF files. I found a Bentley Plantflow brochure, but...
View ArticleNo Gaskets on External Report (BOM by Line Number) in OPM CE, why?
No Gaskets on External Report (BOM by Line Number) in OPM CE, why?
View ArticleOPM CE DOESN'T PLACE BOLTS ON WAFER TYPE (RING SPACER) CONNECTIONS USING MY...
OPM CE DOESN'T PLACE BOLTS ON WAFER TYPE (RING SPACER) CONNECTIONS USING MY CREATED FRP SPECIT PLACES GASKETS BUT NOT BOLTS, WONDERING WHAT AM I DOING WRONG ON THE CATALOG/SPECS OR IS THERE A SETTING...
View ArticleCatalog Editor Component Info
HiWhy some predefined component in Catalog editor don't have a drawing with important dimension information? For example PressureGauge. Thanks
View ArticlePipeline Service Selection list OpenPlant modeler
Hello,is there a way to predefine in a workspace (Project Administrator), a list of service (or unit/plant area) like steam, water, nitrogen, to be chosen from, and eliminate option to create a new...
View Article