Quantcast
Channel: OpenPlant | AutoPLANT Forum - Recent Threads
Browsing all 4153 articles
Browse latest View live

OPIM V8i - Sight Glass Custom Component

Is it possible to have Sight Glass as an option in Custom Pipe Components?

View Article


OPM CE Upd 9 Projectwise workspace and Isometric Styles

HiI have setup OPM to use a PW workspace according to...

View Article


Image may be NSFW.
Clik here to view.

cable ladder

During we use the BRCM to design our cable ladder/tray model. We use OGLAEND systems.The BRCM cable ladder and tray are only can show some flat bar.But for the ladder on site, there also some hole for...

View Article

Image may be NSFW.
Clik here to view.

Valves' Name not show in Isometric drawing

The background is we added a property called C_REMARK in 3D schema, and make it read this.NAME (only at Fluid Regulator class)Then, we found out this property only show on the isometric drawing that...

View Article

Image may be NSFW.
Clik here to view.

Section cut for sheet using OPM Connect Edition

See section cut below. I have my clipping plain(Forward) ending at the mid-point of the tanks, yet I am still seeing objects that are outside of the set clipping plane. Is there a simple solution to...

View Article


Image may be NSFW.
Clik here to view.

Update components failed

FAILED TO DETERMINE when I select the component update tool I was faced the error in AUTO PLANT PIPING I shared screen shot as given below,  could give the answer how to modified the error.

View Article

OPM - CEU8 - service.txt

Where does service.txt live in Connect? I see this needs to be added to the Schema, but not clear on where the file lives.Thanks,

View Article

OPIM 9.1 - How to populate textnodes from excel with padded spaces as...

History:  I have a working configuration that will pull data from an excel spreadsheet and populate textnodes in the isometric.Problem:  It works great for regular text in the excel worksheet, but when...

View Article


OPM - CEU8 - Workset Location

With a number of application to run, I'd like to separate them at the Workset level by application using:_USTN_WORKSETROOT      =...

View Article


Image may be NSFW.
Clik here to view.

The length and length effective of a pipe with socket

In our detailed design of a model, we found the automatically generated length and length effective of a pipe with socket can't meet our request. As shown in the screen shot,when we modeled a  pipe...

View Article

Image may be NSFW.
Clik here to view.

Export file dgn to pxf

Where can I find option export file to pxf (autopipe)? I have OpenPlant Modeler Connect 10.07.00.32

View Article

Image may be NSFW.
Clik here to view.

How to change the default bend radius in intelligent line manager in V8i SS6

I want to change the default corner radius in intelligent line manager, but every time I open this window, the default radius factor was 1.  Because this model has thousands of pipelines, so I don't...

View Article

OPM CE Update 9 : How to enable greyed out properties in EC Schema?

We currently migrated from OPM SS6 to OPM CE Update 9, and thus migrated the workspace as well, and updated schema from OpenPlant_3d.01.07.ecschema.xml to OpenPlant_3d.01.08.ecschema.xml. There are...

View Article


OPM CE - GCS

Are there any issues to be aware of if we model in OpenPlant using a GCS like MGA94 Zone 50?Thanks,

View Article

Image may be NSFW.
Clik here to view.

Unhandled error while opening OP Specification

While trying to open a specification via the OP "Specification Generator", I get the following error message:I have tried to open other Spec from other projects and also get the same error.I am using...

View Article


Adding A New Descriptive Field To Updateable Component Data - Oracle Database

What is the procedure to update a new field while in Oracle DB working environment?Regards,Ramesh.P.K.

View Article

Image may be NSFW.
Clik here to view.

OP Iso Manager - Window Extent Limitation

Hi, while using Open Plant Connect Edition Update 8 - Version 10.08.00.51, I try to produce Isometric drawings on an A1 sheet (Client supplied).The default windows extent is quite small relative to the...

View Article


Image may be NSFW.
Clik here to view.

OPM CE - Project Administrator - Editing Specs

I've turned my attention to sorting out issues with PA and while my workspaces and worksets seem to be loading fine, when I go to load a spec via Spec Generator I get:I have checked the Preferences and...

View Article

OPM CE - Autofit Mitred Bends

Is it possible to have mitred bends place as standard instead of elbows?

View Article

Image may be NSFW.
Clik here to view.

OPM CE - Component Error When Placed Rotated

We've come across an issue with free placed components in a rotated position.Our plant is rotate off from north and the designers are placing mitred bends and then running pipe to them. Only issue is...