OPIM V8i - Sight Glass Custom Component
Is it possible to have Sight Glass as an option in Custom Pipe Components?
View ArticleOPM CE Upd 9 Projectwise workspace and Isometric Styles
HiI have setup OPM to use a PW workspace according to...
View Articlecable ladder
During we use the BRCM to design our cable ladder/tray model. We use OGLAEND systems.The BRCM cable ladder and tray are only can show some flat bar.But for the ladder on site, there also some hole for...
View ArticleValves' Name not show in Isometric drawing
The background is we added a property called C_REMARK in 3D schema, and make it read this.NAME (only at Fluid Regulator class)Then, we found out this property only show on the isometric drawing that...
View ArticleSection cut for sheet using OPM Connect Edition
See section cut below. I have my clipping plain(Forward) ending at the mid-point of the tanks, yet I am still seeing objects that are outside of the set clipping plane. Is there a simple solution to...
View ArticleUpdate components failed
FAILED TO DETERMINE when I select the component update tool I was faced the error in AUTO PLANT PIPING I shared screen shot as given below, could give the answer how to modified the error.
View ArticleOPM - CEU8 - service.txt
Where does service.txt live in Connect? I see this needs to be added to the Schema, but not clear on where the file lives.Thanks,
View ArticleOPIM 9.1 - How to populate textnodes from excel with padded spaces as...
History: I have a working configuration that will pull data from an excel spreadsheet and populate textnodes in the isometric.Problem: It works great for regular text in the excel worksheet, but when...
View ArticleOPM - CEU8 - Workset Location
With a number of application to run, I'd like to separate them at the Workset level by application using:_USTN_WORKSETROOT =...
View ArticleThe length and length effective of a pipe with socket
In our detailed design of a model, we found the automatically generated length and length effective of a pipe with socket can't meet our request. As shown in the screen shot,when we modeled a pipe...
View ArticleExport file dgn to pxf
Where can I find option export file to pxf (autopipe)? I have OpenPlant Modeler Connect 10.07.00.32
View ArticleHow to change the default bend radius in intelligent line manager in V8i SS6
I want to change the default corner radius in intelligent line manager, but every time I open this window, the default radius factor was 1. Because this model has thousands of pipelines, so I don't...
View ArticleOPM CE Update 9 : How to enable greyed out properties in EC Schema?
We currently migrated from OPM SS6 to OPM CE Update 9, and thus migrated the workspace as well, and updated schema from OpenPlant_3d.01.07.ecschema.xml to OpenPlant_3d.01.08.ecschema.xml. There are...
View ArticleOPM CE - GCS
Are there any issues to be aware of if we model in OpenPlant using a GCS like MGA94 Zone 50?Thanks,
View ArticleUnhandled error while opening OP Specification
While trying to open a specification via the OP "Specification Generator", I get the following error message:I have tried to open other Spec from other projects and also get the same error.I am using...
View ArticleAdding A New Descriptive Field To Updateable Component Data - Oracle Database
What is the procedure to update a new field while in Oracle DB working environment?Regards,Ramesh.P.K.
View ArticleOP Iso Manager - Window Extent Limitation
Hi, while using Open Plant Connect Edition Update 8 - Version 10.08.00.51, I try to produce Isometric drawings on an A1 sheet (Client supplied).The default windows extent is quite small relative to the...
View ArticleOPM CE - Project Administrator - Editing Specs
I've turned my attention to sorting out issues with PA and while my workspaces and worksets seem to be loading fine, when I go to load a spec via Spec Generator I get:I have checked the Preferences and...
View ArticleOPM CE - Autofit Mitred Bends
Is it possible to have mitred bends place as standard instead of elbows?
View ArticleOPM CE - Component Error When Placed Rotated
We've come across an issue with free placed components in a rotated position.Our plant is rotate off from north and the designers are placing mitred bends and then running pipe to them. Only issue is...
View Article