Quantcast
Channel: OpenPlant | AutoPLANT Forum - Recent Threads
Browsing all 4153 articles
Browse latest View live

[OP U9] list of fixes

Hi,Same as last time, can I please get a list of fixes in U9? Best regards,Tuan Le

View Article


Image may be NSFW.
Clik here to view.

Importing newly added cable UDA

Hi All,We implemented a new cable UDA over the options menu.However, when we try to modify the import XML file with our newly added attribute doesn't appear there for selection, how can we add it...

View Article


Image may be NSFW.
Clik here to view.

OPM V8i - Iso Splitting

This is driving us nuts. Even placing iso breaks and turning component break off, OPIM wants to break iso's into multiple sheets with either one or no components on. All suggestions welcome, happy to...

View Article

LDB Lock Files

We are having an issue I have never seen before. A user keeps getting locked out of his model and loosing work when another user opens a drawing that is xref'ing his model. We have checked every...

View Article

Image may be NSFW.
Clik here to view.

Elbow dimension discrepancy in Plantwise

the attached image is elbow dimension of 4" pipeline in Plantwise 150mm which is derived from pipeline dimeter.But the real dimension is 152.4mm. Actually there is an option to retrieve dimension from...

View Article


OPM & OPIM SS6 - isometric continuation with pipeline in reference file

Hi all,How to do isometric extraction with a continuation line where the continuation (pipeline) is in a reference file.Looking forward to your help.Best regards.Salim

View Article

OPM SS6 - Copy any element with Tag information without change

Hello all,When I copy a valve or any element with a Tag id from the active file or reference file, the number changes.Example: before copy 200-HV-256 => after copy 200-HV-1325.How to ensure that the...

View Article

Welds to Inherit Schedule and Material of Joint

Trying to determine on how to get the welds to inherit the schedule and material of the joints. We need to generate a weld list from OPM Reporting to include Size, Material, Schedule.Thanks,Jgarza

View Article


Image may be NSFW.
Clik here to view.

OPM V8i - Support or Holder on Valves

We have a number of big items including valves and basket strainers, including custom, that require a pipe leg support or at least the ability for us to be able to model a place holder for the...

View Article


[OpenPlantModeler C#]Dose anyone knows how to get elementid from IECInstance?

I found a way to get all pipe of current plant in OPM SDK's example as follow :ECInstanceList pipeInstances = DgnUtilities.FindInstancesAndLoadRelated("PIPE", false, "PIPING_COMPONENT_HAS_PORT", true);...

View Article

Image may be NSFW.
Clik here to view.

OPPA CE update 8 remains in hang

Hi community,on my Window 10 workstation I've installed OPM CE update 8, OPIM CE update 8 e OPPA CE update 8. When I launch OPPA it stays in hang and the only choose is to kill its process. I've tried...

View Article

Image may be NSFW.
Clik here to view.

OPM V8i - Reset Model Attributes

I've had some users change levels in an OPM file.Is there a way to reset the model so that the levels and colours correct themselves?Tried the usual options.Thanks,

View Article

Image may be NSFW.
Clik here to view.

OPPA CE update 9 crash !!

Hi community,on my Window 10 workstation I've installed OPM CE update 9 and OPPA CE update 8. Launching OPPA it crash. I've tried to reinstall all CE programs, cleaning first all the files from...

View Article


Image may be NSFW.
Clik here to view.

MDL Error: Unable to load library (DLL or MDL Shared Library)

I am getting an error while trying to use an MDL custom functionality. Please find the attached image below: I am using OpenPlant V8i SS6 along with ProjectWise Explorer Connection Edition 329. We have...

View Article

Image may be NSFW.
Clik here to view.

OPM V8i - GRP Flange Type

Looking for some guidance. First time setting up a GRP spec and not sure what type to put the flanges against.Pic below, suggestions welcome.Basically these butt up to end of pipe and are then wrapped. 

View Article


ProjectWise version for transition from OP SS6 to OP Connect

Trying to plan transition from OP SS6 to OP Connect U9 tools set. We are running into issue with our ProjectWise version.For SS6 we observe that every time we put PW 140 and above on the machine, Iso...

View Article

How to ChangeSpec/ChangeSize of valves without the loss of the operator?

When we change the Specification or the Dimension of Valves via Pipeline Manager the Operators are disappearing. We have to place every valve again or the operator itself. Is there a way to change...

View Article


Image may be NSFW.
Clik here to view.

How to create drop down list for a property in OPPID CONNECT EDITION

I was trying to create a drop down list for a property I added to PID schema, but I can't find value map in Classes as in OPMThen, I tried to using the StandardValues Attribute to accomplish it....

View Article

OPIM crashed!

communities.bentley.com/.../1212.i.dgnI created a ISO_SHEET in OPM, when i create the ISO the OPIM crashed without any information. Anyone Can help me? and point out the key issue!  thanks!

View Article

BRCM clearing database after equipment import

Hi all,How is it possible to reset the project database after an equipment import?We are having the problem that importing equipment on a fresh project works just fine, however just the first time....

View Article
Browsing all 4153 articles
Browse latest View live