[OP U9] list of fixes
Hi,Same as last time, can I please get a list of fixes in U9? Best regards,Tuan Le
View ArticleImporting newly added cable UDA
Hi All,We implemented a new cable UDA over the options menu.However, when we try to modify the import XML file with our newly added attribute doesn't appear there for selection, how can we add it...
View ArticleOPM V8i - Iso Splitting
This is driving us nuts. Even placing iso breaks and turning component break off, OPIM wants to break iso's into multiple sheets with either one or no components on. All suggestions welcome, happy to...
View ArticleLDB Lock Files
We are having an issue I have never seen before. A user keeps getting locked out of his model and loosing work when another user opens a drawing that is xref'ing his model. We have checked every...
View ArticleElbow dimension discrepancy in Plantwise
the attached image is elbow dimension of 4" pipeline in Plantwise 150mm which is derived from pipeline dimeter.But the real dimension is 152.4mm. Actually there is an option to retrieve dimension from...
View ArticleOPM & OPIM SS6 - isometric continuation with pipeline in reference file
Hi all,How to do isometric extraction with a continuation line where the continuation (pipeline) is in a reference file.Looking forward to your help.Best regards.Salim
View ArticleOPM SS6 - Copy any element with Tag information without change
Hello all,When I copy a valve or any element with a Tag id from the active file or reference file, the number changes.Example: before copy 200-HV-256 => after copy 200-HV-1325.How to ensure that the...
View ArticleWelds to Inherit Schedule and Material of Joint
Trying to determine on how to get the welds to inherit the schedule and material of the joints. We need to generate a weld list from OPM Reporting to include Size, Material, Schedule.Thanks,Jgarza
View ArticleOPM V8i - Support or Holder on Valves
We have a number of big items including valves and basket strainers, including custom, that require a pipe leg support or at least the ability for us to be able to model a place holder for the...
View Article[OpenPlantModeler C#]Dose anyone knows how to get elementid from IECInstance?
I found a way to get all pipe of current plant in OPM SDK's example as follow :ECInstanceList pipeInstances = DgnUtilities.FindInstancesAndLoadRelated("PIPE", false, "PIPING_COMPONENT_HAS_PORT", true);...
View ArticleOPPA CE update 8 remains in hang
Hi community,on my Window 10 workstation I've installed OPM CE update 8, OPIM CE update 8 e OPPA CE update 8. When I launch OPPA it stays in hang and the only choose is to kill its process. I've tried...
View ArticleOPM V8i - Reset Model Attributes
I've had some users change levels in an OPM file.Is there a way to reset the model so that the levels and colours correct themselves?Tried the usual options.Thanks,
View ArticleOPPA CE update 9 crash !!
Hi community,on my Window 10 workstation I've installed OPM CE update 9 and OPPA CE update 8. Launching OPPA it crash. I've tried to reinstall all CE programs, cleaning first all the files from...
View ArticleMDL Error: Unable to load library (DLL or MDL Shared Library)
I am getting an error while trying to use an MDL custom functionality. Please find the attached image below: I am using OpenPlant V8i SS6 along with ProjectWise Explorer Connection Edition 329. We have...
View ArticleOPM V8i - GRP Flange Type
Looking for some guidance. First time setting up a GRP spec and not sure what type to put the flanges against.Pic below, suggestions welcome.Basically these butt up to end of pipe and are then wrapped.
View ArticleProjectWise version for transition from OP SS6 to OP Connect
Trying to plan transition from OP SS6 to OP Connect U9 tools set. We are running into issue with our ProjectWise version.For SS6 we observe that every time we put PW 140 and above on the machine, Iso...
View ArticleHow to ChangeSpec/ChangeSize of valves without the loss of the operator?
When we change the Specification or the Dimension of Valves via Pipeline Manager the Operators are disappearing. We have to place every valve again or the operator itself. Is there a way to change...
View ArticleHow to create drop down list for a property in OPPID CONNECT EDITION
I was trying to create a drop down list for a property I added to PID schema, but I can't find value map in Classes as in OPMThen, I tried to using the StandardValues Attribute to accomplish it....
View ArticleOPIM crashed!
communities.bentley.com/.../1212.i.dgnI created a ISO_SHEET in OPM, when i create the ISO the OPIM crashed without any information. Anyone Can help me? and point out the key issue! thanks!
View ArticleBRCM clearing database after equipment import
Hi all,How is it possible to reset the project database after an equipment import?We are having the problem that importing equipment on a fresh project works just fine, however just the first time....
View Article