How to insert a PFD and P&ID diagram of the autocad in a OpenPlant?

Is it possible to insert diagrams made in Autocad Plant 3d in Open Plant?

View Article


Image may be NSFW.
Clik here to view.

BleedRing w 45deg flg outlet ISO symbol

We have trouble generating an ISO symbol for this. Can anybody pls help. See attached imageAll help is much appreciated

View Article


Image may be NSFW.
Clik here to view.

Orifice Assembly

We have an orifice assembly as in attached image.Can anybody help us make this as a Custom OPM_component, with Isometric symboloyAny help is much appreciated

View Article

Image may be NSFW.
Clik here to view.

Renaming a raceway system

Hi All,When you open the raceway router, the first thing to select is the system.In which XML file do I have to change which variable to rename for example the "cable tray"?Thank you in...

View Article

Image may be NSFW.
Clik here to view.

How to Upgrade Schema From OpenPlant CONNECT Update 7 to Update 8 Version

HelloI use OpenPlant Project Administrator CONNECT Edition update8, requirement is to upgrade schema from OpenPlant CONNECT Edition Update 7 to OpenPlant CONNECT Edition Update 8.In OpenPlant Project...

View Article


Can I make an OPPID control valve actuator flow dependent?

I have a non-symmetrical control valve actuator (self contained regulator in this case) which needs to have the "tubing" portion of the actuator cell facing the downstream side of the valve at...

View Article

Image may be NSFW.
Clik here to view.

OPM CE Upd8 In drawing reports Item types

HiIn the "In drawings reports"...How do I choose a Item Type that includes several types of item types?For example "Piping Components" or "Supports"

View Article

Image may be NSFW.
Clik here to view.

OPM V8i - Slurry Angle Valve

I have something a little different I need to get into OPM, just not sure if it's possible with the default tools or if it needs to me modelled as a special.Slurry angle valves are not just 45 degrees,...

View Article


OPM V8i - Isometric Scale

Is it possible to set OPIM to use full sheet for all iso's produced? I'm looking for some way to control scale to maximise the iso details on busy lines.Thanks,

View Article


Image may be NSFW.
Clik here to view.

OPM CE Update 8, Reset Part IDs

Hello all,I have made some components with component state existing in my model and I don't want them to appear at BOM. I have excluded the by modifying the reporf.def -file by this EXCLUDE =...

View Article

Instrument Module loads but tab does not

We are having an issue where when the instrument module is loaded the tab/menu doesn't appear. The palette does appear. Does anyone know how to remedy this?

View Article

Image may be NSFW.
Clik here to view.

Problem saving equipment configuration

Hi, after created new equipments to CADLIB_ElectricParts.cel, Equipment Manager don't let me saved new configurations. Pops up the next message "Can't save, because the folder equipment is read only"

View Article

OPM V8i - Drawing Creation

What is the accepted method to create drawing views from an OPM model without having the gasket and bolt cells come through?Thanks,

View Article


OPM V8i - Dummyleg as Support

I was surprised to see dummyleg appear under pipe in the iso instead of support. What's the easiest way to change this so that dummylegs come out in supports in the iso BOM?

View Article

OPM V8i - Iso Break Placement

We'd like to split a few iso's, but want to split the iso's at the end of a flange and not parly way along a pipe, but OPM won't let us place the Iso Break Point here. Any reason why?

View Article


Image may be NSFW.
Clik here to view.

Autoplant modeler V8i Project Database Error ATDB0719: Relationship Manager...

I get the following error when trying to place equipment.Any ideas?

View Article

Image may be NSFW.
Clik here to view.

OpenPlant Orthographics Manager CONNECT Edition

各位老师好。在使用OpenPlant Orthographics Manager CONNECT...

View Article


Image may be NSFW.
Clik here to view.

OPM Ce Update 8, Select Component Instance Window is not showing

Hello all,For some reason when I press the Select Component Instance -button, the dialog is not showing up eg. in valve placement. There is plenty of different valves in my spec and I'm able to change...

View Article

Image may be NSFW.
Clik here to view.

How to add item type: FASTENER in "in drawing reports"(OPM CE UP8)

HiHow to add item type: FASTENER in "in drawing reports"?

View Article

Image may be NSFW.
Clik here to view.

Regarding the ISO drawing, PIPE_LATERAL_TEE_REDUCING_ONE_RUN_AND_BRANCH three...

HiAs shown in the figure below, it is a 100*80*50 reducing Lateral TAs shown in the ISO drawing below, the size in Reports does not show the size of the branchAs shown in the figure below, it is the...

View Article