[OPM U6] Bend point coordinate in report
Hi,Is there a way to include bend point coordinates of pipe bends in OPM report? Best regards,Tuan Le
View Articlespecgen hangs ?
Have found that if editing lookup table, SpecGen hangs.Is this a known issue?
View Articlemacro to place ecannotation
good morning I would like to create a macro that inserts an annotation and makes it a text. exactly the order would be the following: 1 place annotation (inside there is a function annotation) 2 drop...
View ArticleOPIM idgn opening problem
Hello, I have problem with opening idgn files with OpenPlant Isometric Manager. I get an error:[10.01.2020 19:21:38] Loading 1...
View ArticleBOM Pipe Cut Lengths Incorrect
In AutoPLANT when running a BOM, the Quantity dimensions (cut lengths) are in inches, but the actual dimension given is not correct.For example if a pipe is drawn in at 100", the BOM is listing the cut...
View ArticlePlace Flow_Orifice_Plate without the Flange Set?
Hi everybody, I was wondering if there is a possibility to place an Orifice Plate without the corresponding flange set. For example if I want to place an orifice directly to an nozzle on a tank.Also I...
View ArticleHow to cascade Normal Operating Pressure value from Pipeline to Valve OPM CE6
Hello,In OpenPlant Modeler - when I place a valve on a pipeline, I would like it to have the same Normal Operating Pressure value as my pipeline.Anyone could help me with a hint how to do it? I am...
View ArticleMigrating from OpenPlant Modeler V8i to OpenPlant Modeler Connect pipe specs
Hi,I have 3D models that were created via OPM V8i and I need to use them with OPM Connect. When I open the V8i models the specs are gone for existing piping new and old. I need to be able to use the...
View ArticleHow to customize instrument tag?
Hello,I was wondering how to change Instrument text in PID? Currently it shows Instrument name on top and number below. Our actual tag iz customized and includes unit number. If I hoover over the...
View ArticlePrinting issues in OpenPlant Modeler Connect
Hello all,I am having issues printing drawings from OpenPlant Modeler Connect Edition. I am using the same pen table I used in OpenPlant Modeler Connect Edition V8i. Please see below for...
View ArticleUnistrut library
Hello,Is there a unistrut library that we can download and use in OP Modeler to place pipe supports?
View ArticleOPPID SS6 How to control model validation contents
Hello All,For OPPID SS5, model validation doesn't check if the valve specification matches piperun specification, no error will show even no specification filled on the valve. But in SS6, model...
View ArticleOPM Component with different ratings PSV
Have issues with connecting components which have different ratings on ports, typically a PSVThis is defined in Catalog as:
View ArticleCreate saved view from Pipeline manager
Hello,I`m struggling with creating a saved view. What I want is:Goto Pipeline Manager, check pipelines I`m interested in, highlight them or isolate and now create saved view of these particular...
View Articleopm ce Nozzle Locator dgnlib
Is there, or does anyone know of a way to assign a level for a NozzleLocator based on dgnlib expression?We would like to have a level naming like:Nozzle_<<EquipmentName>>
View Articleopm ce NozzleLocator reference
We have Piping and Equipment in separate files.We would like to be able to place NozzleLocators in Piping file, referencing Equipment Name from referenced Equipment file. Is there a way to achieve this?
View Article