Quantcast
Channel: OpenPlant | AutoPLANT Forum - Recent Threads
Browsing all 4153 articles
Browse latest View live

Error creatin spec from specification generator

Hi,I have a problem when I try to create or modificate a spec from specification generator. I can work with the program but, when I try to save the changes, an error appears: "Error occurred adding...

View Article


BPCom32Domain has stopped working

I installed OPIM 10.01.00.23 before installing AutoPLANT Modeler 08.11.14.124 as recommended in the "known issues" section of the OPIM ReadMe.  These are installed on Windows 10.While I don't get the...

View Article


AP Project Information Differs dialog

Regarding the AP Project Information Differs dialog is there a configuration setting that will force the choice to Yes without user input?I don't need to see this dialog in this case (I moved some...

View Article

Mixed Metric environment in OPPID CONNECT

How can we setup a Mixed Metric environment in new OPPID CONNECT?

View Article

Image may be NSFW.
Clik here to view.

Convert DGN to DWG Isometrics

Hi all,normaly we are working only with OPM and OPIM and use only dgn format. For a new offer we need to convert our iso's to dwg format. The nice option in OPIM is that it can generate dwg too.The...

View Article


P&ID Document settings

When opening a P&ID and running the Plant project/Synchronize routine, all changed or missing objects are listed. Including the P&ID Document settings, such as Plant Area, Service, System and...

View Article

OPM Connect Symbology Error

HI ,If anyone has working example for OPM Connect Symbology named expression , please share,I have tested it on OPM connect 10.01.00.23 out of box configuration , it's not working, and also created SR...

View Article

Bentley setup

any download link

View Article


Image may be NSFW.
Clik here to view.

[OPSE V8I] Once open opse, it raise an system fault 99?

I could open my opse normally yesterday, but I could not open it today, and it raise an system fault 99?How to solve it?

View Article


OPPID plant project synchronize to database error

When plant project  synchronize to database, I get the errors:8-27-18 11:45:57 LOG_ERROR - Bentley.Plant.CommonTools.Logging - Database Error: Conversion for instance (InstanceId:0000000198,...

View Article

"AutoPLANT Connection Failed. PLease check exception log" - can't create...

We receive the message in the title when we attempt to generate an isometric using the latest version of the software as of 8/27/18. This is the case with real projects as well as out-of-box sample...

View Article

Sepesific Text Node in Different Level than others

How can I assign a sepesific Text Node, for example Weld Report (NN=62), to be in a different level than all other Text Nodes?User wants to be able turning on and off this report from display in...

View Article

Turning display of specific Cell on and off

How can I turning display of specific Cell on and off in isometric drawing?For example, user wants to turn off the display of only PARTID cells in iso drawing.Like Level Display tool but for cells.

View Article


Option to disable annoying popups for prompting user to add project to CONNECT

While this can be accomplished easily with a script, we would like to know if there is a switch or option to disable the popups that show up in various facets of AutoPLANT and ProSteel, prompting the...

View Article

Image may be NSFW.
Clik here to view.

Bentley Project Packager V8i error - Invalid procedure call or argument

I've had an open Bentley Service request going on 3 weeks now, which Bentley has been unable to resolve.  I'm getting an "Invalid procedure call or argument" error when using Project Packager.  Has...

View Article


Image may be NSFW.
Clik here to view.

SpecGen: Create New Catalog. Placing FLEX HOSE in OPM. Not sure which (or...

When I create a new catalog using the catalog editor in SpecGen, I edit the Schema, then Add Table.At this point, do I have to select one of the table names from the drop-down list, or can I create an...

View Article

OPM SS6 VBA interface

Hi,Is there any vba api available for OPM? I can't seem be able to find any help file for vba that's specific to OPM.Best regards,Tuan Le

View Article


Can you use Clash Detection on nested references in OPM?

I set up my Projects using nested references, divided by discipline:Example:I) Project.dgn        1) Arch.dgn              1a) A-BLDG-1.dgn              1b) A-BLDG-2.dgn        2) Elec.dgn...

View Article

Batch Overwrite Pipe Line Properties

Hi GentsI would like to ask if there is some fast way to update/change line properties in OPM.it's quite normal that our line list with some definition changed, in this case we have to go through the...

View Article

How can I create PE fittings and create a poly pipe (no tagging requirements)...

I have to create a PE fitting to attached the a flange off a ball valve. The Polyethylene pipe in this instance coming off the valve won't have a tag as it isn't required. How can I do this?

View Article