OPM & OPIM SS6 - How to add Plan Area (Tag) for all component without piping...
ih,How to add Plan area in all compoent (Valve, Strainer, instrument, ...) without piping.Exemple for Valve : Plan Area -> 492 / Device Type Code -> HV / Number -> 002Best Regards, Salim
View ArticleHow to add EC_Class_Name property to Bolts and Supports
Is there a way to add the EC_Class_Name to other objects in the report session inside a model so I can group all items by EC_Class_Name in a report.We are not using Project wise so is there a Schema...
View ArticleAutoplant Viewbase?
Hello;Can someone please tell me hoe to do viewbase, because every time I viewbase my distillation tower it doesn't shows up on the lay out tab. thanks
View ArticleExtract DB info from OpenPlant Models
Is it possible to extract DB info from the Models themselves when the projects are standalone?No central DB.ThanksSteve
View ArticleViewport: How to show tangent lines on orthographic view?
Hello;I am very new for using Autoplant Modeler Vi8 (Select Series 8), so can you guys please help me. I am trying to put a tangent line on my object on a viewport orthographic view but I having a...
View ArticleMy OPSE can not be opened normally!!!
My OPSE can not be opened correctly today, and pop-up a message box.The content is : current project is invalid or not set,Support Engineering commands will be disabled. Would you like to continue...
View ArticleLap Joint stub end and slip_on_flange
when I insert the component "Lap Joint stub end" ,the program place automatically another component : "lap joint flange"; where can I change this option and insert the "slip_on_flange" ?
View ArticleRe: Lap Joint stub end and slip on flange [AutoPLANT | AXSYS | OpenPlant |...
Hello Michele, I believe you have posted twice here.-Regards | Rahul Kumar On 05-Mar-2018, at 10:55 PM, Michele Salvagno <bounce-cebab3fc-d550-47c8-b649-5c7a2205501d@communities.bentley.com>...
View ArticleAutoPLANT/ProjectWise reload references
Hi,Using AutoPLANT SS8 V8i (08.11.13..211) with ProjectWise CONNECT Edition (10.00.03.49)When working in a piping model, the Reload References pops up every time it is set to. It seems that even if...
View Article关于OPM中Level Manger中所有的层不能够重命名和不能够编辑中文名字的问题
OPM中Level Manger中所有的层不能够重命名和不能够编辑中文名字的问题,请问有解决办法吗
View Article关于OPM中弯头中心线偏离的问题
老师,您好! 最近在使用OPM建立等级库的过程中,使用的管道标准是“GB/T 3091-2015 低压流体输送用焊接钢管”,管件的标准“GB∕T 12459-2017 钢制对焊管件 类型与参数”SPEC使用中,管径小于DN65的长半径90°弯头的中心线总是偏的,所以在画管道的时候,弯头和管道接口的地方不能对齐,具体见图片,这应该怎么解决呢?在线急等!!!!
View ArticleOPIM incorrectly separating material in BOM after inline instrument
If an inline component from the instrument module (i.e. orifice flange set) is inserted in a line, OPIM will separate the material after the orifice flange from other identical material. This material...
View ArticleOpenPlant PID external datasource to Excel
Hi,I want to add a picklist to some properties using an Excel external datasource. I've implemented it based on document "How to create a pick list on EC Property using External Datasource definition"...
View ArticleMaterial Grads found Blank to generate a new Piping specification in OPM
I am a new user of OPM and want to generate a new Piping specification in Spec Gen. of OPM follow the below stepsOpen OPM spec Gen.Add a catalog of ASME from Path...
View ArticleWhat are important parameter For LapJoint Stub End to its creation in...
Hi,I am creating a record for LapJoint Stub end along with flange but anyhow graphics/created element is not forming in entered dimension. It seems that there is some relation/equation that overrides...
View ArticleHow to draft pipeline in OPPID by MVBA code
Hello All,I have some PSPID drawings, we need convert it to OPPID drawing.I can get all PSPID pipeline vertics and pipeline information. I'm going to draft them again in OPPID by MVBA code. I have...
View ArticleX-REFs disappear from layer manager when Piping loaded
AutoPlant Modeler V8i Select Series 6 08.11.11.135AutoCAD 2014ProjectWise V8i 08.11.11.590We have one model in one project that has multiple x-refs. When the model is opened in AP Modeler (without...
View ArticleStandard Preference dialog, link to classes?
When you open task bars in OPM it associates itself with the Standard Preferences. I believe using the “Associated Task Panes” custom attribute it links the Task bar to the Piping Component Class....
View ArticleHVAC pipelines and levels disappeared from model
It's not the 1st time when me and my colegues have lost levels and pipelines (tags) but have never lost it in HVAC systems. Maby someone will know the answer what to do. Model is attached.View:...
View ArticleOPM SS6 - how to create a customized operator
Hello,I want to create custom operator from specificationWhat are the attributes to add?Best regards, Salim
View Article