In OPPID: how can I obtain the specified level which classfication by service...
For example,In OPPID,when I drawing pipeline, using by Major Pipeline tool, item of sevice :EG, see 1.png. as I see the information of the pipeline, in level displayed :Major Process,see 2.png.In...
View ArticleAutoplant Reinforcing Pad not shown in bill of materials of isometric...
Good ay,Reinforcing pads are not listed in the bill of materials of the isometric.Please notice that the reinforcing pad symbol is shown (as seen below)Versions in use:Autoplant version: 8.11.11.135...
View ArticleThere is a question for OpenPlant Specification Generator.
There is a question for OpenPlant Specification Generator. Is there user input & Keyin fields ? I can’t find it. I want to need a various display and description of material and manufacture as per...
View ArticlePopulating Titleblock Information in Isosheet Manager
Product: OpenPlant Modeler V8i (SS5) 08.11.09.440I'm looking for a way to quickly populate titlebock information and revision history with in Isosheet Manager. My thoughts were that this would be very...
View ArticleOPPID: Handle for Manipulation
No handle is shown on selecting pipeline, equipment etc. please tell me how to get active handle
View Articlewhy items in dialog
in OPPID interface,some items in the same dialog,problem 1: how to make the items all in the same Base Component Annotation List dialog, see picture : problem 2: how to make the items all...
View ArticleHow to get my need annotation type?
In article “How to Have Strainers Tag With a Bubble like Control Valves”, there is a class “STRAINER” . in the class, Add a new property and name it INSTRUMENT_BUBBLE_CLASS. Add custom attribute...
View ArticleTurn off field dimensioning for field components?
We have a project that wants to make all piping of a system field material. This means that all welds are field welds and IsoManager dimensions the field welds.We have turned off the Dimension Field...
View Articleabout instrument line
As I drawing instrument line, I find in my file, the line style of instrument line change into “0”, not specify line style ,see follow picture,why?
View ArticleIso Extractor OPSE
We have modeled piping in OPM, supports in OPSE.Generating ISO's goes on 'forever' (only for lines which have supports modeled in OPSE)Have run besm UpdateRelationships in OPSE.What are we missing?
View ArticleAP OPIM - Dimension discrepancy on socket fittings
Does anyone know how to set/fix dimension discrepancy on socket fittings?For example, for 2" Tee or Elbow, each leg should be dimension as 38 mm, but currently it dimensioned one leg 38 mm and one leg...
View ArticleOP integrated WorkSpace in File Mode
We are working on implementing the following products from OP suite, File BasedWe would prefer an integrated WorkSpace for all modulesHave integrated OPM, OPIM & OPSECurrently working on...
View ArticleOPM SS6 - Grid report with multiple item types
Hi,Just wondering if it is possible to create a grid report that can include multiple items in its query? What we are trying to do is to have grid report containing piping_components, bolts and...
View Articlewhy is not display filename ?
As I build new component,at create tool dialog step,it seems that only the filename is PIDProjectSymbols.dgnlib can display in dialog ,otherwise it can not display in here, is right?
View Articlewhy can not manipulate custom component?
In OPPID, I define a legend , In schema, class named is BOUNDARY_LINE.I set values in component custom attributes, such as enabled mirror、move、rotate、scaler and so on.see 1.pngAs I place the legend, I...
View ArticleHow to drag custom equipment by vertex?
In oppid, user define equipment cell, as place equipment, I hope drag the cell by vertex,such as place vessel,see 1.png, how to do it ?
View ArticleHow to display only one flow arrow in pipeline?
In OPPID, i hope only one flow arrow in every pipeline, such as specify at start point or end point ,see 1.png ?
View ArticleOPM SS6 - Cannot change pipeline with multiple tapping connection to another...
Hi,It seems I can't change a pipeline to another spec if there are 2 or more tapping connections on that pipeline. I've done a test on using the default mEX-OPM.mdb spec as well. My version is...
View ArticleIsometric Continuations with nested references
We are finding that we are not getting any continuations on our isometrics if the referenced sheet we are connecting to has a nest depth of 1 or more.Is this a known issue or a setting perhaps? Sheet 1...
View Articlehow to auto place pipeline tag as draw pipeline?
As I draw pipeline, I hope the pipeline tag followed by ,such as place equipment ,the name of equipment as followed ,how to solve it ?
View Article