OpenPlant Isometric Manager does not update distances to supports
Hello,We are finding that after some revisions to our models when we regenerate an isometric the distances to supports are not correct. I haven't been able to clearly identify why some do and others...
View ArticleOPPID, Plant Component Edit
Hi,Using OPPID SS6In te Drawing settings window, Plant tab. Edit button stays greyed out, can't edit existing items.SH
View ArticleOPPID, Valve replacement, Symbol
Hi,Using OPPID SS6When using Replace menu to replace a valve type. Most of the valve are related to the same symbol.Gate Valve: HVALVE_GATE_OPENSH
View ArticleOPPID, Parser reguler expression and slash character
Hi,Using OPPID SS6When using the slash / symbol in properties like Sizes or Services. If these properties are part of the name object (ex.: Pipeline) the Parser regular expression get wrong value.Any...
View ArticleATDB0801: Unable to update drawing name in drawing's data dictionary
AutoPLANT Modeler SS6 08.11.11.135Add customer XREF to existing ProjectWise model fileSave changes to ProjectWise and the error is displayed.Microsoft Office 2010Windows 7 Professional SP 1This error...
View ArticleOpen AutoPlant drawing from ProjectWise does not return to last used folder
ProjectWise V8i 08.11.11.590AutoPLANT Modeler SS6 08.11.11.135AutoCAD 2014 SP1When opening a drawing or attaching x-ref from ProjectWise the open file dialog does not return to the last used folder in...
View ArticleWindows 10
Does OPPID and OPM run under Win10 yet?Where do I find the readme files that has that in it?Thanks
View ArticleOPIM SS6 - B0 bolt label
Hi,Once in a blue moon, OPIM will have B0 bolt label attached to a flange that continue onto the next sheet of a same pipeline. Is there anyway to prevent this? Best regards,Tuan Le
View ArticleOPIM SS6 - dimension of gasket and spectacle blinds/ring spacer combined
Hi,With spectacle blinds and ring spacer, even when "Dimension gaskets" is turn on in OPIM, only 1 gasket get dimensioned, the other is combined with the ring spacer. Is there anyway to have all...
View ArticleHow to define user fonts and annotations in OpenPlant Orthographics Manager...
As mentioned,there is only several fonts in OPOM. I want to use custom fonts to replace the default fonts.how to do?
View ArticleHow to use the Key Plan Hatching in OpenPlant Orthographics Manager V8i(OPOM)?
What's the function,and how to use?
View ArticleA question about the equipment name defined in OpenPlant Orthographics...
It cannot be shown in the drawings when the equipment name is non-english (e.g. Chinese or Japanese),how to solve?
View ArticleWhere is the access of Grid System Import/Export function within...
The issue is that, the managed workspace including gridlines.txt & GridModels.dgn was ready and it really works for users to refer the Gridmodels or produce isometrics. But when someone else was...
View ArticleOpenPlant Specification Generator Duplicate SYS_ID's From More Than One Spec...
We are having trouble with duplicate SYS_ID's showing up in OPM when spec components reference the same catalog item, and are looking for a solution.For starters, our catalog is set up without material...
View ArticleOPPID, Units measurement, Symbol modification
Hi,Using OPPID SS6, schema 1.07I'm trying to change the unit of the valve's design pressure.Pressure shows lbf/in2 (Gauge)Need psigSH
View ArticleHELP
I am very confused about why I installed the Openplant V8i serise 5 after opening to show a series of errors, such as a photo
View ArticleHow to add bolt/gasket at equipment nozzle?
If we place flange at equipment nozzle, there will be bolt/gasket added. If we deleted the bolt/gasket for some reason, how to add them again? I tried to check connectivity, it is an open end, no...
View ArticleOPPID Repeat Insertion
What is the (Component Custom Attribute) setting to stop Repeat Insertion with the Reset Button
View Article