OPM-SS6 - Gasket and Bolt missing from upgraded spec and catalog

Hi,I'm trialling upgrading existing AutoPlant specs and catalogs to OPM SS6. So far things seem so good, except for not being able to see gasket and bolt.I've attempted to follow the wiki article for...

View Article


Adding a new Vessel/Tank types to OpenPlant Modeler equipment list

Hello, Bentley team!I have a question about custom equipment in OpenPlant Modeler. How can I add a new equipment geometrical types( like cubic tanks) to already existing equipment in  OpenPlant Modeler...

View Article


DataManager, Default path for report

Hi,AutoPLANT SS7 .239ProjectWise .590Office 2010Where do I set the default path for PDF reports sent from DataManager?SH

View Article

Datasheets, ProjectWise default path

Hi,AutoPLANT SS7 .239ProjectWise .590Office 2010Where do I set the default path for datasheets?Default is ...<ProjectName>\Datasheets\Instrumentation\SH

View Article

AutoPlant Catalog conversion to OpenPlant Catalogs

I have a series of AutoPlant customised catalogs and I have tried ALL the docummented processes to convert them to OpenPlant Catalogs.I either get a blank spec or Error "Selected spec is incompatable...

View Article


Pipe profiles + Inroads DTM

Hello.I've got pipe model made in OpenPlant Modeler which is underground, and terrain model from Inroads. I need to generate profiles consist of chainage, ground elevation and invert levels, everything...

View Article

How to set a long bolt for wafer component in OpenPlant

My company's workspace has a problem, for wafer components, bolts were added in both ends, just like flange. In another workspace, the bolt is correct. I'd like to know where to control the bolt for...

View Article

Is there a easy way to select all bolts which used on different end...

For example, I'd like to select all bolts of wafer component, is it possible?

View Article


Olet problem in OpenPlant

I found some problems about olet.1. Auto branch table is OK. If try to place a brach by snap to the main pipe, it will place the component defined in branch table. I did some test, if the main pipe...

View Article


How to revise pipeline information efficiently

We have a problem here, the user inputed line number in wrong attributes. For example, there is line Area1-Service1-No1-Spec1, we should inpu Area1 in Area / Service1 in Service / etc. Unfortunately...

View Article

Autoplant object enabler

I am looking for an up to date object enabler for AutoCAD 2015~2016.I have several discussions for this, I have looked at them and have not come to a conclusion on any of them.They all point to a...

View Article

Image may be NSFW.
Clik here to view.

OpenPlant Modler adding custom tank

Hello to BENTLEY Family!I have a question about adding a new parametric equipment to OpenPlant Modeler.I have already add a new TANK (Cubic Tank) eqiupment to the toolbox in program by modifying a...

View Article

How to fill pipeline attributes in batch

The user just inputed line number only, no other attributes inputed, such as Temp/Press/etc. We can input them manually, but it would be a hard job.I'd like to know if any easy way to do it, any batch...

View Article


What's the bolt/gasket selection rule at spec break

I'd like know what's the rule for bolt/gasket selection when change pipe spec. And if connected to nozzle, what will happen if nozzle is assigned a different spec or empty. Thanks a lot!

View Article

Is it possible to filter iso name in OPIM

For example, there are hundreds of pipelines in a i-model, they will list in OPIM. It list the pipelines by Iso Sheet/Area/Service/Unit right now. If I need to extract some pipelines, for example,...

View Article


Modifying a custom component after placement

Is there any way to modify a custom component that was created and placed in the model?We have a non-standard component. The user created a custom component and placed it in the model. We later learned...

View Article

Image may be NSFW.
Clik here to view.

OPPID: How to pass document property to a valve tag

Hello,I am trying to pass a value from a document property to a valve tag.  Example below:Any suggestions are welcome.Thanks,Sal Gomez

View Article


OpenPlant Project Setup

Can anyone tell me how to share a Project that is sitting on the Company Network.It has been created Using OPModeller_Metric as the base and then a new Workspace & Project created onto the company...

View Article

iModel composer SS4 with PSDS Error

I am trying to export PlantSpace (XM) data to an iModel and I'm using iModel Composer (SS4) with my PSDS config loaded to point to the correct odbc and ams & ams_user.lib etc.When I try and open a...

View Article

Open Plant Modeler doesn't work after OP-Project Adminstrator installation

Dear all,we have installed OP-Modeler Version 08.11.09.404After installing the Project Administrator 081109564, Open Plant stopped working.Trying to start Open Plant, following error message Comes...