We are using AutoPLANT with OPIM. In one of our projects we have AT_PLINE_PIPE spools, some of which are flanged and some are not. The flanged spools accumulate as a count in the iso BOM while the non flanged spools accumulate as a total length. We would like the non flanged spools to accumulate as a count as well. Since the flanged spools already accumulate this way it leads me to believe that the accumulation method is dictated by the spool's end conditions. I looked in the schema but can't tell where this is controlled. How can I get non flanged AT_PLINE_PIPE spools to accumulate as a count rather than length in the OPIM BOM?
↧