RE: OPPID SS5: adding jumper to crossing pipes

$
0
0

Hello Justinas,

I read the article, That did the trick, I can now change the size of the gap. Thank you!

Now this is out of the way I bump up to an other problem. I know I can reapply the jump in an existing pipe by means of the command "pid piperun jumpcomponents". When I do this I get the error:

6-11-14 11:57:00 LOG_ERROR - Bentley.Plant.Application.Pid - Exception : Object reference not set to an instance of an object.  Stack Trace :     at Bentley.Plant.ApplicationFramework.Schematics.Catalog.SchematicsRun.JumpComponents(IRange range, Int32 sectionIndex)

   at Bentley.Plant.ApplicationFramework.Schematics.Catalog.SchematicsRun.JumpComponents()

   at Bentley.Plant.ApplicationFramework.Schematics.Catalog.SchematicsRun.ReevaluateJumpers()

   at Bentley.Plant.Application.Pid.PidApplication.JumpComponentsForRun(String unparsed)

Any experience on this?

Kind regards.